background image

D7044 | Installation Instructions | 4.0

 

Installation

 

4.0

 

Installation

 

Complete all wiring before mounting the D7044 and faceplate.

 

1.

 

Wire the D7044 according to Figures 3 and 4 on page 3.

 

2. Mount the D7044 on a standard double-gang box (Figure 5) or 4 in. x 4 in. electrical box (Figure 6).

 

Figure 5: Mounting the D7044 on a Double-Gang Box

 

1

 

2

 

3

 

1

 

0 1 A

 

      2

 

      0

 

2 1 B

 

    9 0 1

 

82

 

              37

 

    64

 

        5

 

    9 0 1

 

82

 

              37

 

  64

 

        5

 

1 - Supplied mounting screws (4)

 

2 - D7044 Module

 

3 - Double-gang box

 

Figure 6: Mounting the D7044 on an Electrical Box

 

1

 

2

 

3

 

1

 

0 1 A

 

      2

 

      0

 

2 1 B

 

  9 0 1

 

82

 

73

 

    6 54

 

        0 19

 

                28

 

73

 

    6 5 4

 

1 - Supplied mounting screws (2)

 

2 - D7044 Module

 

3 - 4 in. x 4 in. electrical box

 

4

 

Bosch | 10/04 | 48337D

 

Содержание D7044

Страница 1: ...D7044 Installation Instructions EN Multiplex Single Input Module ...

Страница 2: ...ices 1 0 Description The D7044 Figure 1 is a general purpose device that connects a contact device to the FACP multiplex bus with a supervised input loop Figure 1 D7044 Features 1 2 3 Test the FACP according to NFPA 72 0 1 A 2 0 1 B2 9 0 1 82 73 6 5 4 9 0 1 82 73 6 5 4 4 1 2 3 4 Status LED Zone input terminals Mux bus loop terminals Rotary address switches All operating power for the D7044 is draw...

Страница 3: ...ansion Module with the DS9400M FACP 1 2 21 k end of line EOL resistor UL Listed P N 25899 2 Zone in 3 Zone in Note The maximum zone wire resistance 100 Figure 4 Loop and Panel Wiring Connections Figure 2 shows the A address range set at 095 allowing the D7039 to work with the D7024 FACP 3 0 Wiring Ensure all power is removed before making electrical connections Failure to do so can result in perso...

Страница 4: ...ng box Figure 5 or 4 in x 4 in electrical box Figure 6 Figure 5 Mounting the D7044 on a Double Gang Box 1 2 3 1 0 1 A 2 0 2 1 B 9 0 1 82 37 64 5 9 0 1 82 37 64 5 1 Supplied mounting screws 4 2 D7044 Module 3 Double gang box Figure 6 Mounting the D7044 on an Electrical Box 1 2 3 1 0 1 A 2 0 2 1 B 9 0 1 82 73 6 54 0 19 28 73 6 5 4 1 Supplied mounting screws 2 2 D7044 Module 3 4 in x 4 in electrical ...

Страница 5: ...n 3 Secure the faceplate to the front of the D7044 Figure 7 Figure 7 Mounting the Faceplate 2 1 D7044 3 0 1 A 2 0 2 1 B 9 0 1 82 73 6 5 4 0 19 82 73 6 5 4 1 Supplied mounting screws 2 2 Faceplate 3 D7044 Module on electrical box Bosch 10 04 48337D 5 ...

Страница 6: ... for specific programming information Refer to the D7039 Installation Instructions P N 38685 or the DS9431 Installation Instructions P N 41381 for multiplex wiring information Alarm 550 Standby 550 Nominal 12 V 32 F to 120 F 0 C to 49 C Maximum of 93 non condensing UL 864 California State Fire Marshall CSFM Table 1 Control Panel Programming Type Control Panel Requirements Multiplex Bus Average Cur...

Страница 7: ...D7044 Installation Instructions Notes Notes Bosch 10 04 48337D 7 ...

Страница 8: ...Bosch 130 Perinton Parkway Fairport NY 14450 9199 USA Customer Service 800 289 0096 Technical Support 888 886 6189 2004 Bosch 48337D ...

Отзывы: