background image

Bosch | 6/04 | 49323C

2

D285DH 

| Installation Instructions |

FCC Notice

The D285DH Photoelectric Duct Smoke Detector
complies with Part 15 of the Federal Communication
Commission (FCC) Rules. Operation is subject to the
following conditions:

The detector might not cause harmful interference.

The detector must accept any interference received,
including interference that can cause undesirable
operation.

Changes or modifications not expressly approved by
Bosch can void the user’s authority to operate the
D285DH detector.

1.0

Introduction

The D285DH is a UL Listed detector designed for use
with commercial fire protective signaling systems and
household fire warning systems. Refer to the National
Fire Alarm Code (NFPA 72).

When properly installed using the D285 Series
Dectectors, tamper protection is provided by the
positive power line in/out wiring. This causes the
control to initiate a trouble signal when a detector is
removed from its base. The master control provides
two-wire system supervision. An end-of-line (EOL)
resistor, specified by the control manufacturer, provides
four-wire supervision.

2.0  Specifications

Table 1:     Specifications 

 

Description 

Only requires a base. “B” is the UL 
compatibility identifier. Refer to the  
Two-Wire Smoke Detector Compatibility 
Technical Service Note
 (P/N: 31866) to 
determine the identifier used with the 
D340 Series Duct Housing. 

Operating 
Temperature 

+32°F to +100°F (0°C to +38°C) 

0 to 95% relative humidity  
(non-condensing) 

Voltage and 
Current 

Refer to the D340 Duct Detector 
Installation Instructions 
(P/N: 48188) and 
the D341/D342

 

Duct Detector 

Installation Instructions (P/N: 48196) for 
voltage and current. 

Power-up 
Time 

22 sec maximum 

Two-wire: 

Refer to the Two-Wire Smoke Detector 
Compatibility Technical Service Note
 
(P/N: 31866). 

Note: Bosch makes no claim written, oral, 

or implied the D285DH works with 
any two-wire control panels except 
those specified in the 

Two-Wire 

Smoke Detector Compatibility 
Technical Service Note

 

(P/N: 31866). 

Compatible 
Control 
Panels 

Four-wire:

 

Compatible with all UL Listed four-wire 
control panels. Refer to the 
manufacturer's installation instructions for 
proper EOL resistor selection.

 

 

1.0

Introduction

Содержание D285DH

Страница 1: ...D285DH EN Installation Instructions Photoelectric Duct Smoke Detector ...

Страница 2: ...e system supervision An end of line EOL resistor specified by the control manufacturer provides four wire supervision 2 0 Specifications Table 1 Specifications Description Only requires a base B is the UL compatibility identifier Refer to the Two Wire Smoke Detector Compatibility Technical Service Note P N 31866 to determine the identifier used with the D340 Series Duct Housing Operating Temperatu...

Страница 3: ...tor D285DH Installation Instructions 3 0 Mounting Figure 1 Mounting the Base 1 Base contacts three sets 2 Start the detector contacts at these three places and rotate the base clockwise 1 R2 3 1 2 1 2 2 1 3 When the system is free of alarms check each detector to ensure the red LED head indicator flashes approximately every 4 sec This verifies the detector is receiving power and operating properly...

Страница 4: ...ver tab away from the chamber cover Then pull the chamber cover up and away from the chamber refer to Item 2 in Figure 3 6 Remove dust and debris from the chassis area using clean dry compressed air or a vacuum 7 Replace the chamber to ensure the hole for the LED is properly aligned over the LED Align by placing the chamber parallel to the chassis and gently snapping the locking tabs into place 8 ...

Страница 5: ...tivity 6 2 Magnet Test Place a magnet horizontally against the recess in the duct housing cover and observe the LED If the detector is within the factory marked calibration range it goes into alarm and the Alarm LED latches ON If the detector is too sensitive the LED on the head flashes six times rapidly once every 1 2 sec Then the detector goes into alarm If the detector is not sensitive enough t...

Страница 6: ...Bosch 6 04 49323C 6 D285DH Installation Instructions Notes ...

Страница 7: ...7 Bosch 6 04 49323C D285DH Installation Instructions Notes ...

Страница 8: ...Bosch 130 Perinton Parkway Fairport NY 14450 9199 USA Customer Service 800 289 0096 Technical Support 888 886 6189 2004 Bosch 49323C ...

Отзывы: