Part II: System Commands
WALK TEST ? (C 4 + 4)
D1260 Owner’s Manual
© 2003 Bosch Security Systems
50410C
WALK TEST ? (C 4 + 4)
Walk Test
Description
Use this function to test command centers, detection devices, and sounders (both interior and exterior) to be certain they
function properly. You can review untested points at your command center to help pinpoint any problems.
You cannot arm your system while in the walk test mode, and no alarm reports are sent to your security company unless
a 24-hour point is activated (such as fire or panic). A Walk Test Start Report may be programmed to be sent to your
security company.
Upon initiation, the walk test will test the burglary bell pattern on the bell output and ring the command center burglary
bell for 2 seconds. The AC will be disabled for 4 minutes in order to test the system’s battery power. If the battery cannot
maintain the system for the 4-minute period, the command center will appear to go dead. If your command centers are
programmed to be supervised, the main alarm panel will beep intermittently during this 4-minute period. If this
happens, contact your security company. At the end of the 4-minute period, AC is returned to the system and the panel
restores. To test individual detection devices, simply activate sensors and open protected doors and windows one-at-a-
time. As each detection device is faulted, the Command Center emits a brief tone and the display indicates for 60 seconds
that the point has been tested. This verifies that each detection device is working properly.
Using Walk Test
:
1.
Ensure your command center shows idle disarmed
text.
2.
Press the
COMMAND
key.
3.
The display shows
*System Command*
.
4.
Press the
4
key, followed by the
4
key.
+
Note:
If you prefer, you may use the Command Menu in place of steps 2 and 3 to initiate this function.
Press the Menu> soft key to enter the Command Menu,
then press Next> soft key repeatedly
until you reach the
WALK TEST ?>
prompt then press the
adjacent soft key.
5.
The burglary bell sounds for 2 seconds. When the
display shows
### points remain to be tested
you can
begin. (### is the number of points)
Note:
If you know the point number, you can enter it by pressing its number key and then the
ENTER key.
The display will change to show the point that was entered. If the point is invalid the message “Invalid Point” or
“This is not a valid walk point” appears.
Содержание D1260 Series
Страница 2: ...D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Страница 4: ...Contents D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Страница 6: ...Introduction About This Owner s Manual D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 14: ...Part I Security System Basics Fire Alarms D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Страница 20: ...Part I Security System Basics Silencing an Alarm D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Страница 32: ...Part II System Commands MASTER ARM COMMAND 1 D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 36: ...Part II System Commands PERIMETR INST COMMAND 2 D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 38: ...Part II System Commands PERIMETR DELAY COMMAND 3 D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 42: ...Part II System Commands VIEW MEMORY COMMAND 4 0 D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 80: ...Part III Advanced Commands CHG SKEDS COMMAND 5 2 D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 100: ...Part III Advanced Commands DEFAULT TEXT COMMAND 5 7 D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 104: ...Part III Advanced Commands DISPLAY REV COMMAND 5 9 D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 110: ...Part III Advanced Commands SERVICE MENU 9 9 Enter D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 124: ...Part IV Multi Area Use Turning Off the System D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 144: ...Appendix Passcode Worksheet D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 152: ...Appendix Security System Glossary D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Страница 154: ...D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...