background image

Explanation of symbols and safety instructions

59

Climate Room Control – 6721841498 (2022/04)

1

Explanation of symbols and safety 
instructions

1.1

Explanation of symbols

Warnings

In warnings, signal words at the beginning of a warning are used 
to indicate the type and seriousness of the ensuing risk if 
measures for minimizing danger are not taken.

The following signal words are defined and can be used in this 
document:

DANGER

DANGER

 indicates that severe or life-threatening personal 

injury will occur.

WARNING

WARNING

 indicates that severe to life-threatening personal 

injury may occur.

CAUTION

CAUTION

 indicates that minor to medium personal injury may 

occur.

NOTICE

NOTICE

 indicates that material damage may occur.

Important information

The info symbol indicates important information where there is 
no risk to people or property.

1.2

General safety instructions

H

Notices for the target group

All system-relevant instructions must be 
observed. Failure to comply with 
instructions may result in material 
damage and personal injury, including 
danger to life.

▶ Installation, inspections, repairs, 

modification and relocation must be 
done by a qualified installer or service 
company.

▶ Before carrying out the installation, 

read the installation instructions of all 
system elements.

▶ Observe the safety instructions and 

warnings.

▶ Follow national and regional 

regulations, technical regulations and 
guidelines.

▶ Record all work carried out.

H

Intended use

▶ Use the product only to control air 

conditioning split units.

All other use is considered unsuitable. 
Any damage resulting from prohibited 
operations is excluded from liability.

H

Safety of electrical devices for 
domestic use and similar 
purposes

The following requirements apply in 
accordance with EN 60335-1 in order to 
prevent hazards from occurring when 
using electrical appliances:
“This appliance can be used by children 
of 8 years and older, as well as by people 
with reduced physical, sensory or 
mental capabilities or lacking in 
experience and knowledge, if they are 
supervised and have been given 
instruction in the safe use of the 
appliance and understand the resulting 

Содержание CRC R-1

Страница 1: ...elési útmutató 112 it Istruzioni per l installazione e l uso 123 Climate Room Control CRC R 1 lt Montavimo ir valdymo instrukcija 134 lv Instalācijas un lietošanas instrukcija 145 mk Упатства за инсталација и ракување 156 nl Installatie en gebruikersinstructies 167 pl Instrukcja montażu i obsługi 178 pt Instruções de instalação e funcionamento 189 ro Instrucțiuni de instalare și utilizare 200 sk N...

Страница 2: ... and time 62 5 3 Setting main operating mode 63 5 4 Setting the room temperature 63 5 5 Setting timer 63 5 5 1 One time ON OFF timer 63 5 5 2 Weekly ON OFF timer 64 5 5 3 Weekly event timer 64 5 5 4 Additional settings for weekly timer 65 5 6 Setting the swing function 65 5 6 1 Indoor unit with vertical and horizontal swing function 65 5 6 2 Indoor unit with vertical swing function 65 5 6 3 Indoor...

Страница 3: ... to comply with instructions may result in material damage and personal injury including danger to life Installation inspections repairs modification and relocation must be donebyaqualifiedinstallerorservice company Before carrying out the installation readtheinstallationinstructionsofall system elements Observe the safety instructions and warnings Follow national and regional regulations technica...

Страница 4: ...chnical data Table 26 3 Installation 3 1 Prior to installation Carefully read the technical documentation of the indoor unit outdoor unit and other system components and determine a suitable installation location Theambienttemperatureattheinstallationlocationshould be in the following range 5 43 C The relative humidity at the installation location should be in the following range 40 90 Do not inst...

Страница 5: ...nnect the earthing terminal lug Insert the button battery into the holder 1 4 Configuration to the wired room controller Call up the configuration menu and make the settings Switch off the air conditioning system Keep theCOPY key pressed until a parameter appears in the display If several indoor units are detected the address e g 00 appears initially With the or key select an indoor unit 00 16 and...

Страница 6: ...oom controller with the address 0 B secondary wired room controller with the address 1 Init ON restore factory settings Key Function K Switch on off M Set operating mode DAYOF F Day off deletion Adjust up down setting Confirm choice TIMER Set timer Fan step d Navigate back Set swing function FUNC Set function COPY Copy adopt data Parameters Description Pos Symbo l Explanation 1 Display of main ope...

Страница 7: ...y until appears on the display Press the or key to set the required temperature The fan speed cannot be adjusted in automatic mode Cooling mode Press the M key repeatedly until appears on the display Press the key until the required air speed is reached Press the or key to set the required temperature Dehumidification mode Press the M key repeatedly until appears on the display Press the or key to...

Страница 8: ...he display Wait for a few seconds while the setting is saved The unit now starts the next activity cycle following a delay of 1 hour Press the DAY OFF key 3x until 2h appears on the display The unit now starts the next activity cycle following a delay of 2 hours 5 5 3 Weekly event timer Setting timer Up to 8 events can be set for each day to change the operating mode temperature and fan speed Keep...

Страница 9: ...coolingmode for an extended period condensate may be discharged Adjusting the louvre by hand may cause faults Only usethe wiredroom control orremote control to adjust the louvre The function and availability of the swing function depends on the indoor unit 5 6 1 Indoor unit with vertical and horizontal swing function Automatic vertical swing mode up down Press the key The symbol appears To cancel ...

Страница 10: ...r units rotate Default setting the indoor units rotate every 10 hours Confirm with key Press the or key to set the maximum temperature 26 32 C once the set temperature has been reached both appliances are switched on in cooling mode The Rotation function is interrupted until 24 C has been reached no maximum temperature to interrupt the Rotation function Confirm with key Press the or key to adjust ...

Страница 11: ...Assembliescanthereforebe sorted by composition and passed on for recycling or disposal Old electrical and electronic appliances This symbol means that the product must not be disposed of with other waste and instead must be taken to the waste collection points for treatment collection recycling and disposal The symbol is valid in countries where waste electrical and electronic equipment regulation...

Страница 12: ...Climate Room Control 6721841498 2022 04 276 1 i 1 2 3 5 4 6 7 0010040461 003 2 120 20 120 60 84 19 46 44 0010035291 001 3 4 0010040476 001 1 2 3 1 2 3 4 0010040477 001 ...

Страница 13: ...277 Climate Room Control 6721841498 2022 04 5 6 1 2 0010040394 001 0010035298 001 2 1 1 2 2 1 1 7 8 1 0010040366 001 CN40 1 2 3 0010042010 002 9 1 2 0010040466 001 ...

Страница 14: ......

Страница 15: ......

Страница 16: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...

Отзывы: