Inputs and Outputs
–
One RS-232 interface port COM3 (middle connector on the CPU terminator card)
for connection to an automation computer.
–
One RS-232 interface port COM4 (upper connector of CPU terminator card) for
connection to an external serial printer, a PC, a modem, or a network.
–
One parallel printer port for connection to a parallel printer
–
Two programmable inputs (wire harness included)
–
Two programmable outputs (wire harness included)
–
Optional: One RS-232 port (COM1) for the Network Communications expansion
option (D6600 only).
UL Canada – ULC (D6600
only)
Active
Level
Protect
ed
Premis
e
Backup
Requirements for
Network
Communications
Supervision of
Communication
Channel
Receiver Risk
Level A1
PSDN
UPS power backup
Loss of
Communication
Channel shall be
indicated at SRC
D6600
Low
Level P1
DACT
UPS power backup
Loss of
Communication
Channel shall be
indicated at SRC
D6600
Low