9.1
Specifications – heat pump (alternating current)
Unit
5 OR-S
7 OR-S
9 OR-S
13 OR-S
Air/water operation
Power output with A -10/W35
, 100% compressor
speed
KW
4.37
5.43
7.65
10.50
Power output with A -7/W35
, rated output
KW
4.70
5.93
6.21
11.50
COP with A -7/W35
2.81
2.79
3.18
2.64
Modulation range with A -7/W35
KW
1.5-4.7
1.5-5.9
2.0-8.3
4.0-11.5
Power output with A +2/W35
1)
, 100% compressor
speed
1) Performance data in accordance with EN 14511
KW
5.32
6.26
8.95
13.07
Modulation range with A +2/W35
KW
2-5
2-6
3-9
5.5-13
Power output with A +7/W35
KW
2.14
2.28
3.77
6.86
COP with A +7/W35
, partial load
4.69
5.31
5.02
4.68
Power output with A +2/W35
KW
2.66
3.35
4.36
9.11
COP with A +2/W35
, partial load
4.04
4.16
4.25
3.60
KW
3.99
5.05
4.94
9.06
EER with A 35/W7
2.74
2.64
2.82
2.64
Cooling capacity with A 35/W18
KW
5.92
7.13
7.11
10.89
EER with A 35/W18
3.79
3.46
3.90
3.69
Electrical details
Power supply
230V 1N AC 50Hz 230V 1N AC 50Hz 230V 1N AC 50Hz 230V 1N AC, 50Hz
Protection index
IP X4
IP X4
IP X4
IP X4
Fuse rating for supplying the heat pump directly via
the building connection
2)
2) Fuse class gL/C
A
10
16
16
25
Maximum power consumption
KW
2.9
3.2
3.6
7,2
Performance factor cos phi with maximum output
>0.97
>0.97
>0.96
>0.97
Rated power input of compressor with A -7/W35
rated output
KW
1.67
2.13
1.95
4.36
Performance factor cos phi with A7/W35
>0.97
>0.97
>0.96
>0.97
Heat pump soft start
Yes
Yes
Yes
Yes
Soft start type
Inverter
Inverter
Inverter
Inverter
Max. number of compressor starts
1/h
10
10
10
10
Starting current
<5
<5
<5
<5
Heat transfer medium
Minimum flow
l/s
0.32
0.33
0.43
0.62
Internal pressure reduction
kPa
9.7
7.8
10.5
15.8
Air and noise generation
Max. fan motor output (DC transformer)
W
180
180
180
280
Maximum air current
m³/h
4500
4500
4500
7300
Sound pressure level at a distance of 1 m
dB(A)
39
39
40
47
Sound power
3)
dB(A)
47
47
48
55
Max. sound power
dB(A)
61
63
64
64
Max. sound power "quiet operation"
dB(A)
55
58
58
57
General details
Refrigerant
4)
R410A
R410A
R410A
R410A
Refrigerant charge
kg
1.70
1.75
2.35
3.3
CO
2
(e)
Tonne
3.55
3.65
4.91
6.89
Maximum temperature of flow, heat pump only
°C
62
62
62
62
Installation altitude above sea level
Up to 2000 m above sea level
Dimensions (W x H x D)
mm
930x1380x440
930x1380x440
930x1380x440
1122x1695x545
Weight without walls and top cover
kg
88
89
96
154
Weight with walls and top cover
kg
106
107
114
182