6 720 809 134 (2013/09)
Compress 3000 DW FII
12 | Installation
5.3 Connecting the ducts
The air inlet can be located in the installation room, in a
different room or outside. In the latter two cases, air inlet ducts
must be installed.
When choosing a room for the air inlet, observe the average air
temperature and required air flow rate (
Tab. 3). In order to
minimise air resistance, lay the air inlet and outlet ducts
(Ø 160 mm) as straight as possible.
The length (L
eq
) of the air inlet and outlet ducts must not
exceed the following values:
• 30 m at fan speed SP1
To ensure that condensate forming in the air inlet and air outlet
ducts drains from the appliance:
▶ Install air ducts horizontally or at a slight angle to the air inlet
and air outlet apertures on the top side of the appliance.
Installation with ducts
▶ Activate “Duct” function (
5.3.1 Open flue operation
If the heat pump is operated with air from the installation
location, the volume of the room must be at least 20 m
3
.
5.3.2 Outdoor air operation
If the pump is operated with outdoor air, the ducts must be
protected against the weather using the correct end pieces.
Fig. 9
Equivalent duct length (L)
[1] Air inlet
[2] Air outlet
5.4 Connecting the water pipes
NOTICE:
Possible damage to external
casing!
▶ Do not tilt the appliance on his feet more
than 20°.
To ensure maximum appliance performance
and to prevent condensation forming on the
external duct walls, use thermally and
acoustically insulated ducts.
Air inlet
(IN)
Air outlet
(OUT)
L
eq
0.5 m duct
0.5 m
1 m duct
1.0 m
2 m duct
2.0 m
10 m hose
19.0 m
45° elbow
0.9 m
90° elbow
2.0 m
90° flexible curve
2.3 m
Weather grille
8 m
4 m
Roof output
7 m
4 m
Table 4
L
Fan speed
1)
1)
chapter 8.6.4
Up to 30 m
SP1
Table 5
Never close the water shut-off valve during
operation (
Fig. 6, [4]).
L
2
T
L
T1
L1
C1 C2
L2
L4
L3
L = L1+C1+L2
T1
L = L3+C2+L4
L = L + L
SP1: L 30m
T2
T1
T2
≤
2
1
Содержание Compress 3000 DW FI Series
Страница 29: ...6 720 809 134 2013 09 Compress 3000 DW FII 29 Notes ...
Страница 30: ...6 720 809 134 2013 09 Compress 3000 DW FII 30 Notes ...
Страница 31: ...6 720 809 134 2013 09 Compress 3000 DW FII 31 Notes ...
Страница 32: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...