Set the time for disinfection.
▶ Select the time using the "+" and "-" buttons.
▶ Press "OK".
As soon as the temperature reaches 70 °C, the appliance
switches back to the previously set operating mode.
Activating the manual "Leg" function
▶ Call up the "Leg" function and press "OK".
"
" flashes on the display.
▶ Press "OK".
The "Leg" function is active.
As soon as the temperature reaches 70 °C, the appliance
switches back to the previously set operating mode.
Cancelling the "Leg" function.
▶ Call up the "Leg" function and press "OK".
"
" flashes on the display.
▶ Press "+" until the display shows "LstP".
▶ Press "OK".
The current Legionella program is cancelled.
8.6.4 « Duct » - use of ducts
Fig. 36
« Duct » function
Switching on the « Duct » function
▶ Select « Duct » function and press « OK ».
The display shows “dOFF”.
▶ Press « + » or « - » to define the use of ducts:
– « dOFF » : installation without ducts
– « dON » : installation with ducts
▶ Press « OK ».
8.6.5 "Purg" - Drain
The "Purg" function can be used to drain water from the system.
Fig. 37
"Purg" function
Switching on the "Purg" function.
▶ Call up the "Purg" function and press "OK".
The pump is switched on.
The display indicates the time remaining until the draining
procedure is complete (in minutes).
After 5 minutes, the appliance reverts to the previously
selected operating mode.
8.6.6 "Fset" - Default settings
The "Fset" function can be used to restore the default settings.
Fig. 38
"Fset" function
Switching on the "Fset" function
▶ Call up the "Fset" function and press "OK".
The display shows "Fset".
▶ Press "OK".
After 10 seconds, the default settings are restored
(
chapter 8.9).
8.7 "Info" submenu - Information
With the "Info" function, it is possible to display the total
consumption for the last 30 days.
The DHW temperature is automatically set to
70 °C.
To repeat the disinfection process, you must
reactivate it.
This only ends the current program; the
weekly repetition is still active.
6720807839-01.1V
6720801967-02.1V
6720804054-10.1V
Содержание Compress 3000 DW FI Series
Страница 29: ...6 720 809 134 2013 09 Compress 3000 DW FII 29 Notes ...
Страница 30: ...6 720 809 134 2013 09 Compress 3000 DW FII 30 Notes ...
Страница 31: ...6 720 809 134 2013 09 Compress 3000 DW FII 31 Notes ...
Страница 32: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...