49
-
GAM220MF and GAM270MFL Digital Angle
finder,
Compound
Cut
Calculator,
Protractor, and Level –
Gives you the
information needed to position cuts so that
they fit together precisely even if the room is
out of square.
-
MS1233 Crown Stop Set –
Correctly hold
crown molding in an inclined position against
fence. Set molding for simple vertical
cutting – no compound cutting required.
-
T1B Portable Miter Saw Stand
-
GTA3800 Portable Miter Saw Stand with
Wheels
-
T4B Gravity-Rise Wheeled Miter Saw Stand
-
MS1234 Length Stop
-
Blades
Troubleshooting
▶ Troubleshooting Guide - General
PROBLEM
CAUSE
CORRECTIVE ACTION
Tool vibrates or shakes.
1.
Saw blade not round.
2.
Saw blade damaged.
3.
Saw blade loose.
4.
Other
-
Replace blade.
-
Replace blade.
-
Check that blade is properly
seated on the inner washer.
See Removing and Installing
Blades on page 17.
-
Authorized service.
Head assembly does not
slide freely when attempting
a slide cut.
1.
Slide rail lock knob is engaged.
-
Rotate slide rail lock knob
counter clockwise to
disengage.
Blade does not cut
completely through
workpiece.
1.
Depth stop plate is pulled out
for non-through cuts.
2.
Replacement blade is less than
8-1/2” diameter.
-
Push depth stop plate inward
to set for full-depth cuts (see
page 20).
-
Change to a blade that is fully
8-1/2” diameter.
Saw blade or lower guard
cuts or contacts left sliding
fence when saw is set for
bevel cuts.
1.
Left sliding fence is not moved
out from path of saw blade
before making bevel cut.
-
Move left sliding fence to be
clear of lower guard and saw
blade; perform a “dry cut” to
check for clearances before
making bevel cuts (see page
37).
Accessories and Attachments