10 | Unit Parts 

3. 

Unit Parts 

 

 

Fig. 3.1 

 

NOTE ON ILLUSTRATIONS 
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual 
shape shall prevail. 

Included)

 

(Included)

 

(Included)

 

(Included)

 

(Included)

 

6 720 869 159 (2016/12)

 

Installation Manual

 

Содержание Climate 8000 RAC

Страница 1: ... 8000 RAC All Model Numbers 6 720 869 159 2016 12 Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference Installation Manual 6 720 869 159 2016 12 ...

Страница 2: ...h mounting plate to wall 12 3 Drill wall hole for connective piping 12 4 Prepare refrigerant piping 14 5 Connect drain hose 15 6 Connect signal cable 17 7 Wping and cables 18 8 Connect indoor power wire 18 9 Mount indoor unit 18 5 Outdoor Unit Installation 20 1 Select installation location 20 2 Install drain joint 21 3 Anchor outdoor unit 22 4 Connect signal and power cables 23 6 720 869 159 2016 ...

Страница 3: ...ns Refrigerant Piping 25 1 Cut pipe 25 2 Remove burrs 26 3 Flare pipe ends 26 4 Connect pipes 27 7 Air Evacuation 29 1 Evacuation Instructions 29 2 Note on Adding Refrigerant 30 8 Electrical and Gas Leak Checks 31 9 Test Run 32 10 European Disposal Guidelines 34 Installation Manual 6 720 869 159 2016 12 ...

Страница 4: ...the unit The presence of other gases or substances will lower the unit s capacity and can cause abnormally high pressure in the refrigeration cycle This can cause explosion and injury Do not allow children to play with the air conditioner Children must be supervised around the unit at all times 1 Installation must be performed by a qualified persons Defective installation can cause water leakage e...

Страница 5: ...mmended CAUTION Do not install the unit in a location that may be exposed to combustible gas leaks If combustible gas accumulates around the unit it may cause fire Do not operate your air conditioner in a wet room such as a bathroom or laundry room Too much exposure to water can cause electrical components to short circuit 1 The product must be properly grounded at the time of installation or elec...

Страница 6: ...n water leakage electrical shock and fire or cause the equipment to fail Name Shape Quantity Mounting plate 1 Clip anchor 5 Mounting plate fixing screw ST3 9 X 25 5 Remote controller 1 Fixing screw for remote controller holder ST2 9 x 10 2 Included Remote controller holder 1 Dry battery AAA 2 Air freshening filter 1 Seal 1 for cooling heating models only Drain joint 6 720 869 159 2016 12 Installat...

Страница 7: ...Accessories 7 Name Shape Quantity Owner s manual 1 Installation manual 1 Remote controller illustration 1 Installation Manual 6 720 869 159 2016 12 ...

Страница 8: ...8 Installation Summary Indoor Unit 2 Installation Summary Indoor Unit 6 720 869 159 2016 12 Installation Manual ...

Страница 9: ...Installation Summary Indoor Unit 9 Installation Manual 6 720 869 159 2016 12 ...

Страница 10: ...STRATIONS Illustrations in this manual are for explanatory purposes The actual shape of your indoor unit may be slightly different The actual shape shall prevail Included Included Included Included Included 6 720 869 159 2016 12 Installation Manual ...

Страница 11: ... will not vibrate Strong enough to support the weight of the unit A location at least one meter from all other electrical devices e g TV radio computer DO NOT install unit in the following locations Near any source of heat steam or combustible gas Near flammable items such as curtains or clothing Near any obstacle that might block air circulation Near the doorway In a location subject to direct su...

Страница 12: ...nchors provided Then secure the mounting plate to the wall by tightening the screws directly into the clip anchors Step 3 Drill wall hole for connective piping You must drill a hole in the wall for refrigerant piping the drainage pipe and the communication cable that will connect the indoor and outdoor units 1 Determine the location of the wall hole based on the position of the mounting plate Refe...

Страница 13: ...lates along with the following dimensions Width of mounting plate Height of mounting plate Width of indoor unit relative to plate Height of indoor unit relative to plate Recommended position of wall hole both to the left and right of mounting plate Relative distances between screw holes Correct orientation of Mounting Plate Holesaw 2 kW Models 7 kW Models 5 3 kW Models 3 5 kW Models 2 6 kW Models ...

Страница 14: ...piping This serves two purposes To facilitate the Refrigerant Piping Connection process To facilitate Gas Leak Checks and enable you to check for dents 4 If existing connective piping is already embedded in the wall proceed directly to the Connect Drain Hose step If there is no embedded piping connect the indoor unit s refrigerant piping to the connective piping that will join the indoor and outdo...

Страница 15: ...to prevent leaks 4 For the portion of the drain hose that will remain indoors wrap it with foam pipe insulation to prevent condensation 5 Remove the air filter and pour a small amount of water into the drain pan to make sure that water flows from the unit smoothly NOTE ON DRAIN HOSE PLACEMENT Make sure to arrange the drain hose according to Fig 4 5 DO NOT kink the drain hose DO NOT create a water ...

Страница 16: ...necting power to fixed wiring a switch or circuit breaker that disconnects all poles and has a contact separation of at least 1 8in 3mm must be incorporated in the fixed wiring The qualified technician must use an approved circuit breaker or 7 Only connect the unit to an individual branch circuit outlet Do not connect another appliance to that outlet 8 Make sure to properly ground the air conditio...

Страница 17: ...O LIVE WIRE While crimping wires make sure you clearly distinguish the Live L Wire from other wires 2 Open front panel of the indoor unit 3 Using a screwdriver open the wire box cover on the right side of the unit This will reveal the terminal block WARNING ALL WIRING MUST BE PERRFORMED STRICTLY IN ACCORDANCE WITH THE WIRING DIAGRAM LOCATED ON THE INSIDE OF THE INDOOR UNIT S WIRE COVER 4 Unscrew t...

Страница 18: ...oss the signal cable with any other wiring 2 Using adhesive vinyl tape attach the drain hose to the underside of the refrigerant pipes 3 Using insulation tape wrap the signal wire refrigerant pipes and drain hose tightly together Double check that all items are bundled in accordance with Fig 4 10 DO NOT WRAP ENDS OF PIPING When wrapping the bundle keep the ends of the piping unwrapped You need to ...

Страница 19: ...efer to Electrical Checks and Leak Checks section of this manual 5 After the leak test wrap the connection point with insulation tape 6 Remove the bracket or wedge that is propping up the unit 7 Using even pressure push down on the bottom half of the unit Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate UNIT IS ADJUSTABLE Keep in mind that the hooks on t...

Страница 20: ...rm and solid the location can support the unit and will not vibrate Noise from the unit will not disturb others Protected from prolonged periods of direct sunlight or rain Fig 5 1 DO NOT install unit in the following locations Near an obstacle that will block air inlets and outlets Near a public street crowded areas or where noise from the unit will disturb others Near animals or plants that will ...

Страница 21: ...unit If the drain joint comes with a rubber seal see Fig 5 4 A do the following 1 Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit 2 Insert the drain joint into the hole in the base pan of the unit 3 Rotate the drain joint 90 until it clicks in place facing the front of the unit 4 Connect a drain hose extension not included to the drain joint to redirect wate...

Страница 22: ...20 24 340 13 39 845x700x340 33 25 x27 5 x13 38 7 kW Type 540 21 26 350 13 8 If you install the unit on the ground or on a concrete mounting platform do the following 1 Mark the positions for four expansion bolts based on dimensions in the Unit Mounting Dimensions chart 2 Pre drill holes for expansion bolts 3 Clean concrete dust away from holes 4 Place a nut on the end of each expansion bolt 5 Hamm...

Страница 23: ... cover BEFORE PERFORMING ELECTRICAL WORK READ THESE REGULATIONS 1 All wiring must comply with local and national electrical regulations and must be installed by a licensed electrician 2 All electrical connections must be made according to the Electrical Connection Diagram located on the side panels of the indoor and outdoor units 3 If there is a serious safety issue with the power supply stop work...

Страница 24: ...rew the u lug of each wire to its corresponding terminal 5 After checking to make sure every connection is secure loop the wires around to prevent rain water from flowing into the terminal 6 Using the cable clamp fasten the cable to the unit Screw the cable clamp down tightly 7 Insulate unused wires with PVC electrical tape Arrange them so that they do not touch any electrical or metal parts 8 Rep...

Страница 25: ...rter Split Air Conditioner 4KW 25 82ft 10 33ft Suction 3 8 Liquid 1 4 4 1KW 6KW 30 98 5ft 20 66ft Suction 1 2 Liquid 1 4 6 1KW 7 1KW 50 164ft 25 82ft Suction 5 8 Liquid 3 8 65 213ft 30 98 5ft Connection Instructions Refrigerant Piping Step 1 Cut pipes When preparing refrigerant pipes take extra care to cut and flare them properly This will ensure efficient operation and minimize the need for futur...

Страница 26: ...ipe seal the ends with PVC tape to prevent foreign materials from entering the pipe 2 Sheath the pipe with insulating material 3 Place flare nuts on both ends of pipe Make sure they are facing in the right direction because you can t put them on or change their direction after flaring See Fig 6 3 Fig 6 3 4 Remove PVC tape from ends of pipe when ready to perform flaring work 5 Clamp flare form on t...

Страница 27: ...flare nut as tightly as possible by hand 3 Using a spanner grip the nut on the unit tubing 4 While firmly gripping the nut on the unit tubing use a torque wrench to tighten the flare nut according to the torque values in the Torque Requirements table below Loosen the flaring nut slightly then tighten again Fig 6 7 TORQUE REQUIREMENTS Outer Diameter of Pipe mm Tightening Torque N cm Add Tightening ...

Страница 28: ... pressure does not drop move to the next step If the pressure drops locate leak and repair Repeat this stage once leak is repaired 2 Pressure to 4 15MPa and ensure pressure holds and stabilises Once the pressure is held leave for 24 hours and check pressure If the temperature changes allow 0 01MPa per degree change If correct release nitrogen and start vacuum process If the pressure is not correct...

Страница 29: ...RFORMING EVACUATION Check to make sure that both high pressure and low pressure pipes between the indoor and outdoor units are connected properly in accordance with the Refrigerant Piping Connection section of this manual Check to make sure all wiring is connected properly Evacuation Instructions Before using the manifold gauge and vacuum pump read their operation manuals to familiarize yourself w...

Страница 30: ...d slightly higher than atmospheric pressure Fig 7 2 11 Remove the charge hose from the service port 12 Using hexagonal wrench fully open both the high pressure and low pressure valves 13 Tighten valve caps on all three valves service port high pressure low pressure by hand You may tighten it further using a torque wrench if needed OPEN VALVE STEMS GENTLY When opening valve stems turn the hexagonal...

Страница 31: ...rn off the unit immediately and call a licensed electrician to find and resolve the cause of the leakage Note This may not be required for some locations in the US WARNING RISK OF ELECTRIC SHOCK ALL WIRING MUST COMPLY WITH LOCAL AND NATIONAL ELECTRICAL CODES AND MUST BE INSTALLED BY A LICENSED ELECTRICIAN Gas Leak Checks There are two different methods to check for gas leaks Soap and Water Method ...

Страница 32: ...ller to turn it on 3 Press the MODE button to scroll through the COOL Select lowest possible temperature HEAT Select highest possible temperature 4 Let each function run for 30 minutes and perform the following checks List of Checks to Perform PASS FAIL No electrical leakage Unit is properly grounded All electrical terminals properly covered Indoor and outdoor units are solidly installed All pipe ...

Страница 33: ...ntrol return unit to normal operating temperature b Using insulation tape wrap the indoor refrigerant pipe connections that you left uncovered during the indoor unit installation process IF AMBIENT TEMPERATURE IS BELOW 17 C 63 F You can t use the remote controller to turn on the COOL function when the ambient temperature is below 17 C In this instance you can use the MANUAL CONTROL button to test ...

Страница 34: ... options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal dealers Special notice Disposing of this appliance in the forest or other natural surroundings endangers yo...

Страница 35: ...Notes 35 Installation Manual 6 720 869 159 2016 12 ...

Страница 36: ...Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Bosch Group is a brand name of Bosch Thermotechnology Ltd worcester bosch co uk ...

Отзывы: