background image

Bosch Thermotechnology Ltd 

Cotswold Way 

Warndon 

Worcester 

WR4 9SW
mailto: [email protected] 

Contact Number 03301233004 

Web address www.bosch-industrial.co.uk

Содержание Climate 5000 SCI 18 CAS/ OU- OUE

Страница 1: ...NDITIONER Climate 5000 SCI CL5000SCI 18 CAS OU OUE 24 CAS OU OUE 36 CAS OU OUE 48 CAS OU OUE Owner s Manual Read this manual carefully before installing or operating your new air conditioning unit Ensure to save this manual for future reference ...

Страница 2: ...installation may cause water leakage electric shock or fire The warranty will be void if the unit is not installed by Qualified Personnel If an abnormal situation arises like a burning smell turn off the power supply and call a qualified personel for instructions to avoid electric shock fire or injury DO NOT let the indoor unit or the remote control get wet It may cause electric shock or fire DO N...

Страница 3: ... check the indoor unit to see if anything is damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with other heating devices thoroughly ventilate the room to avoid oxygen deficiency DO NOT climb onto or place objects on top of the outdoor unit DO NOT operate the air conditioner when using fumigant insec ticides The chemicals may become layered ...

Страница 4: ...ailure the angle of the horizontal louvers will automatically return to the previous position The angle of the horizontal louver should not be set too small as condensation may form and drip into the machine To reset the louver press the manual button which will reset the horizontal louver settings Refrigerant Leak Detection System Some Models Intheeventofarefrigerantleak theLCDscreenwilldisplay E...

Страница 5: ...ll wires are connected correctly Failure to connect wires according to instructions can result in electrical shock or fire 4 1 Unit Maintenance BEFORE CLEANING OR MAINTENANCE Always turn off your air conditioning system and isolate the power supply before cleaning or maintenance DO NOT use chemicals or chemically treated cloths to clean the unit DO NOT use benzene paint thinner polishing powder or...

Страница 6: ...d call qualified personnel immediately Refrigerant is both toxic and flammable DO NOT use the air conditioner until the leak is repaired When the air conditioner is installed in a small room measures must be taken to prevent the refrigerant concentration from exceeding the safety limit in the event of refrigerant leakage Concentrated refrigerant causes a severe health and safety threat Refrigerant...

Страница 7: ...starts in HEAT mode after defrosting white mist may be emitted due to moisture generated from the defrosting process The indoor unit makes noises A squeaking sound is heard when the system is OFF or in COOL mode The noise is also heard when the drain pump optional is in operation A squeaking sound may occur after the unit is run in HEAT mode due to expansion and contraction of the unit s plastic p...

Страница 8: ...ak or long term use Check for leaks re seal if necessary and top off refrigerant The unit starts and stops fre quently There is too much or too little refrigerant in the system Check for leaks and recharge the system with refrigerant There is air incom pressible gas or foreign material in the refriger ation system Evacuate and recharge the system with refrigerant System circuit is blocked Determin...

Страница 9: ...model malfunction 10 Off E9 10 Overload protection 1 On F0 11 Outdoor temperature sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge air temperature sensor error 4 On F3 14 Outdoor EEPROM Electrically Erasable Programmable Read Only Memory error 5 On F4 15 Outdoor fan speed DC fan motor only malfunction 6 On F5 16 Auto lifting panel communication error 8 On F7 17 Aut...

Страница 10: ...perature sensor E5 Quick flash 6 Outdoor malfunction Quick flash Quick flash E6 Quick flash Quick flash 7 EEPROM malfunction Quick flash Quick flash E7 8 Water level alarm malfunction E8 Quick flash 9 DC motor speed out of control Quick flash Eb Quick flash 10 Outdoor unit low pressure malfunction Quick flash Quick flash Eb Quick flash 11 Auto lifting panel communication error Quick flash F0 Quick...

Страница 11: ... and other potentially hazardous materials When this appliance is disposed of the law requires special collection and treatment DO NOT dispose of this product as household waste or unsorted municipal waste NOTE Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment Hazardous substances may leak into the ground water and enter th...

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Страница 16: ...Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW mailto Commercial enquiry uk bosch com Contact Number 03301233004 Web address www bosch industrial co uk ...

Отзывы: