background image

Bosch

 

Split-Type Ductless Air Conditioner / Heat Pump

Climate 5000 AA Series

  

User Manual

Содержание Climate 5000 AA Series

Страница 1: ...Bosch Split Type Ductless Air Conditioner Heat Pump Climate 5000 AA Series User Manual ...

Страница 2: ...2 Bosch Split Type Ductless Air Conditioner Heat Pump User Manual 01 2017 Bosch Thermotechnology Corp Data subject to change ...

Страница 3: ...2 Achieving optimal performance 7 2 3 Other features 7 2 4 Setting angle of air flow 8 2 5 Sleep operation 9 3 Manual operation without remote 10 3 1 How to operate your unit without the remote control 10 4 Care and maintenance 11 4 1 Cleaning precautions 11 4 2 Cleaning your air filter 11 4 3 Air Filter Reminders Optional 12 4 4 Maintenance Long Periods of Non Use 12 4 5 Maintenance Pre Season In...

Страница 4: ...lling or operating your new air conditioning unit Make sure to save this manual for future reference WARNING INSTALLATION Installation must be performed by qualified personnel only Inappropriate installation may cause water leakage electric shock or fire All repairs maintenance and relocation of this unit must be performed by a qualified service technician Inappropriate repairs can lead to serious...

Страница 5: ...g Failure to do so can cause electrical shock Do not clean the air conditioner with excessive amounts of water Do not clean the air conditioner with combustible cleaning agents Combustible cleaning agents can cause fire or deformation to the equipment CAUTION If the air conditioner is used together with burners or other heating devices thoroughly ventilate the room to avoid oxygen deficiency Turn ...

Страница 6: ...conds when TIMER ON is set FRESH SWING TURBO or SILENCE features are turned on for 3 seconds when TIMER OFF is set FRESH SWING TURBO or SILENCE features are turned off when defrosting when anti cold air feature is turned on when unit is self cleaning when freeze protection is turned on Display Code Meanings In Fan mode the unit will display the room temperature In other modes the unit will display...

Страница 7: ...unit to prevent ice build up Ice may build up if the unit is unplugged To further optimize the performance of your unit do the following Keep doors and windows closed Limit energy usage by using TIMER ON and TIMER OFF functions Do not block air inlets or outlets Regularly inspect and clean air filters 2 3 Other features Auto Restart If the unit loses power it will automatically restart with the pr...

Страница 8: ... to drip from the unit Setting horizontal angle of air flow CAUTION Do not put your fingers in or near the blower and suction side of the unit The high speed fan inside the unit may cause injury The horizontal angle of the airflow must be set manually Grip the deflector rod See Fig 3 and manually adjust it to your preferred direction Deflector rod The louver can be taken down by releasing the lock b...

Страница 9: ... to go to sleep When in COOL mode the unit will increase the temperature by 1 C 2 F after 1 hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the unit will decrease the temperature by 1 C 2 F after 1 hour and will decrease an additional 1 C 2 F after another hour It will hold the new temperature for 7 hours then the unit will turn off automatically The SLEEP function...

Страница 10: ...trol is strongly recommended Unit must be turned off before manual operation To operate your unit manually 1 Locate the MANUAL CONTROL button on the right hand side panel of the unit 2 Press the MANUAL CONTROL button one time to activate FORCED AUTO mode 3 Press the MANUAL CONTROL again to activate FORCED COOLING mode 4 Press the MANUAL CONTROL button a third time to turn the unit off NOTICE The man...

Страница 11: ...This can cause the panel to deform or become discolored 4 2 Cleaning your air filter CAUTION Do not touch air freshening filter for at least 10 minutes after turning off the unit CAUTION Before changing the filter or cleaning turn off the unit and disconnect its power supply When removing filter do not touch metal parts in the unit The sharp metal edges can cut you Do not use water to clean the in...

Страница 12: ... indoor unit will flash nF This is a reminder to replace your filter After 15 seconds the unit will revert to its previous display To reset the reminder press the LED button on your remote control 4 times or press the MANUAL CONTROL button 3 times If you don t reset the reminder the nF indicator will flash again when you restart the unit Replacement Filters Description Bosch PartNumber 9000 BTU 12...

Страница 13: ...y occur when the louver resets its position A squeaking sound may occur after running the unit in HEAT mode due to expansion contraction of the unit s plastic parts Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units Low hissing sound when the system starts has just stopped...

Страница 14: ...le products Refrigerant At the end of the service life of this appliance and prior to it s environmental disposal a person qualified to work with refrigerant circuits must recover the refrigerant from within the sealed system WARNING Improper disposal of this appliance endangers your health and is bad for the environment Hazardous substances may leak into the ground water and enter the food chain D...

Страница 15: ...User Manual Bosch Split Type Ductless Air Conditioner Heat Pump 15 Bosch Thermotechnology Corp 01 2017 Data subject to change Notes ...

Страница 16: ...United States and Canada Bosch Thermotechnology Corp 50 Wentworth Avenue Londonderry NH 03053 Tel 866 642 3198 Fax 954 776 5529 www boschheatingandcooling com BTC 770001101 C 01 2017 ...