Operation
Climate 6100i/8100i – 6721821568 (2020/11)
8
Effectiveness of this function may differ depending on the room layout,
installation position of the unit, and insulation level of the space
concerned.
3.10.6 Self cleaning mode
Self cleaning mode will reduce the growth of mold fungus with
plasmacluster ions and dry the inside of the unit. Utilize this mode at
seasonal change over terms.
▶ Press the
Clean
button when the unit is not operating.
The remote control displays
for 1 minute.
The blue plasmacluster lamp on the unit turns on.
The unit stops operation after 90 minutes.
To cancel self cleaning mode:
▶ Press the
Stop
button.
The blue plasmacluster lamp on the unit turns off.
Temperature, fan speed, airflow direction or timer can not be set during
self cleaning mode.
Mold fungus already grown can not be eliminated by this operation.
3.10.7 Operation at 10 °C
Heating mode with 10 °C as set temperature is run.
▶ Press the
key to start the heating mode.
▶ Press the
10 °C
key.
The remote control displays
10 °C
while the operation mode is
active.
To cancel the operation mode:
▶ Press the
10 °C
key again.
NOTICE
Operation at 10 °C is not available in automatic mode.
3.10.8 Changing the brightness of the lamps
When the lamps on the unit are too bright:
▶ During operation, press the
Display
button.
The plasmacluster lamp on the unit turns off.
The other lamps become dark.
To light up the lamps:
▶ Press the
Display
button again.
3.10.9 Auxiliary mode
Use this mode when the remote control is not available.
To turn on:
▶ Press the auxiliary button (
Fig. 1, [4]).
The green operation lamp
K
on the unit lights up and the unit starts
operating in auto mode. Fan speed and temperature are set to auto
mode.
To turn off:
▶ Press the auxiliary button again (
Fig. 1, [4]).
The green operation lamp
K
turns off.
3.11
Additional notes on operation
Operating temperature range
Table 10
The built-in protection device may prevent the appliance from operating
at temperatures outside the above range.
Condensation may form at the air outlet if the humidity is higher than
80 % and the appliance operates continuously in Cooling mode. To
prevent this, open the vertical ventilation flaps as wide as possible
(vertical relative to the ground) and set a high fan output.
When power failure occurs
This air conditioner has a memory function to store settings when a
power failure occurs.
After power recovery, the unit will automatically restart in the same
settings, which were active before the power failure, except for timer
settings.
If the timers were set before a power failure, they will need to be set
again.
Preheating function
In heating mode the indoor fan may not start for 2 to 5 minutes after the
unit is turned on, to prevent cold air from blowing out of the unit.
De-icing function
When ice forms on the heat exchanger of the outdoor unit during heating
mode, an automatic de-icer provides heat for about 5 to 10 minutes to
remove the ice. During de-icing, the inside and outside fans stop
operating.
After de-icing is completed, the unit automatically resumes operation in
heating mode.
Heating efficiency
The outside air temperature greatly affects the heating efficiency. If the
heating efficiency is reduced due to low outside temperatures, use an
additional heater.
It takes time to warm up and heat the entire room because of the forced
air circulation system.
Indoor
temperature
Weather
temperature
Cooling
Upper limit
+32 °C
+43 °C
Lower limit
+21 °C
–10 °C
Heating
Upper limit
+27 °C
+24 °C
Lower limit
CL6100i ...
– –20 °C
Lower limit
CL8100i ...
– –25 °C