Project Configurator
3–16
1070 072 262-101 (01.09) GB
Select communication channel for the loading process
Loading can be performed either via the Ethernet interface on the frontside
of the ZS550 module which is totally integrated in the system network and
prescribed for programming or via the Ethernet interface on the backside of
the CON550 module.
L
Select menu PRESETS.
UDP channel options:
D
Retransmission counter indicates how many retransmissions of a tele-
gram are admissible.
D
Maximum response time per protocol indicates the time in ms which
passes when there is no reaction until the telegram is repeated.
L
Select communication channel in the dialog box.
Check or set the IP address for the programming device
The IP address of the programming device has to be located in the same
subnetwork as the IP address of the selected communication channel (front-
side or backside Ethernet interface) of the CL550 system.
L
Set the IP address of the programming device in the dialog box ”Microsoft
TCP/IP Properties” in the WinNT operating system.