Power supply
Specification
Type of power supply:
40W single output, universal input switching power supply
Mains input voltages:
90 .. 264Vac
Input frequency range:
47 .. 63Hz
Max. input current :
0.9A at 100Vac or 0.3A at 240Vac
Nominal output voltage:
24Vdc
Rated output load:
1.7A
Dimensions:
125mm x 75mm
Danger
Heat sink is electrical connected to live of mains input depending on polarity!
4.1.1
Additional technical specification for test environment:
Load range
Output
Min. load
Rated load
Peak load
Voltage
accuracy
+24V
0A
1.7A
2.5A
24 ±0.6V
For a practical load test, connect e.g. a resistor of 15 Ohm (min. 40W) between the ter24V and GND.
Line regulation
Line input
Load
Regulation
Input change 90 .. 264Vac
1.7A
< ±1%
Ripple and noise
Output Test
Conditions
24V with 1.7A load
<1% p-p (rated load)
Oscilloscope with 15Mhz limited
bandwidth
AC input pin assignment K1
1
—
3
L
N
Line
Neutral