Arming the System

 

EN 

| 8 

 

 

Bosch Security Systems | 6/04 | 920036O.OG.162 

 

4.1 Forced 

Arming

 

Forced arming arms the system when a zone is not 
sealed. If the system does not arm and a long beep is 
heard, forced arming is not permitted. In this case, 
you must ensure that all zones are sealed or manually 
isolated before you can arm the system. 

4.2 

Arming in AWAY Mode 

When you leave your premises and require all zones 
to be in a ready state to detect intrusion, you arm the 
system in AWAY Mode.  

There are two different methods for arming the 
system in AWAY Mode. Method one is standard and 
always operates. Method two is optional and can be 
disabled by your installer if you do not want to use 
single button arming. 

Table 9: 

How to Arm the System in AWAY Mode

 

Method One 

Enter your user code followed by the 
[#] button (for example, [2 5 8 0 #]). 
Two beeps are heard and the AWAY 
indicator displays. Exit time starts 
counting. 

Method Two 

Hold down the [#] button until two 
beeps are heard. 
The AWAY indicator displays and 
exit time starts counting. 

4.3 

Arming in STAY Mode 1 

STAY Mode 1 is only used when the perimeter and 
unused areas of the premises need to be armed to 
detect an intruder entering the premises. At the same 
time, this mode allows you to move freely within an 
area that is automatically isolated. 

Only your security company can program zones 
automatically isolated in STAY Mode 1. 

There are two different methods for arming the 
system in STAY Mode 1. Method one is standard 
and always operates. Method two is optional and can 
be disabled by your installer if you do not want to 
use single button arming. 

Entry Guard Timer For STAY Mode 1 

When arming the system in STAY Mode 1, an 
optional entry timer called Entry Guard Timer For 
STAY Mode 1 is used. Use this entry timer to delay 
the sirens if a zone is not automatically isolated and 
triggered an alarm condition. Entry Guard Timer For 
STAY Mode 1 is the delay time used for all zones 
except 24-hr. zones when the system is armed in 
STAY Mode 1 or STAY Mode 2. 

If the Entry Guard Timer For STAY Mode 1 is 
programmed and a zone not automatically isolated is 
triggered, the codepad beeps twice a second until the 
entry timer expires or the system is disarmed. If the 
alarm condition is not reset by entering your user 
code followed by the [#] button (such as, [2 5 8 0 #]) 
before the entry timer expires, the sirens activate into 
alarm. Only your installer can program this feature. 

Table 10:  How to Arm the System in STAY Mode 1 

 

Method One 

Enter your user code followed by the [*] 
button (for example, [2 5 8 0 *]). 
Two beeps are heard and the STAY 
indicator displays. Exit time starts counting. 
Any zones programmed to be automatically 
isolated in STAY Mode 1 flash until exit time 
expires. At the end of exit time, all zones 
selected to be automatically isolated turn off 
and the codepad gives one short beep. 

Method Two 

Hold down the [*] button until two beeps are 
heard. 

The STAY indicator displays and exit time 
starts counting. 
Any zones programmed to be automatically 
isolated in STAY Mode 1 flash until exit time 
expires. At the end of exit time, the zone 
indicators turn off and the codepad gives 
one short beep. 

4.4 

Arming in STAY Mode 2 

STAY Mode 2 is only used when the perimeter and 
unused areas of the premises need to be armed to 
detect an intruder from entering the premises. At the 
same time, this mode allows you to move freely 
within an area that is automatically isolated. Any 
Master Code user can program zones to be 
automatically isolated in STAY Mode 2. 

Entry Guard Timer For STAY Mode 2 

When arming the system in STAY Mode 2, an 
optional entry timer called Entry Guard Timer for 
STAY Mode 2 can be used. Use this entry timer to 
delay the sirens if a zone is not automatically isolated 
and triggered into alarm condition. Entry Guard 
Timer for STAY Mode 2 is the delay time used for 
all zones except 24-hr. zones when the system is 
armed in STAY Mode 1 or STAY Mode 2. 

If the Entry Guard Timer for STAY Mode 2 is 
programmed and a zone, not automatically isolated, 
triggers, the codepad beeps twice a second until the 
entry timer expires or the system disarms. If the 
alarm condition is not reset by entering your user 
code followed by the [#] button (for example,  
[2 5 8 0 #]) before the entry timer expires, the sirens 
activate into alarm. Only your installer can program 
this option. 

Содержание CC880

Страница 1: ...EN Operators Guide Solution 16 Solution 16 Safecom CC880 LP880 SC8016 ...

Страница 2: ...disconnect this equipment should it become physically damaged and arrange for its disposal or repair The transmit level from this device is set at a fixed level and because of this there may be circumstances where the performance is less than optimal Before reporting such occurrences as faults please check the line with a standard telepermitted telephone and do not report a fault if the telephone ...

Страница 3: ... 0 Testing 13 19 0 Event Memory Recall 13 20 0 Day Alarm 13 21 0 Codepad ID and Buzzer Tone 14 22 0 Partitioning 14 22 1 Master Partitioned Codepad Indicators 14 22 1 1 Zone Indicators 14 22 1 2 Area On Off Indicators 14 22 1 3 Area Display Indicators 14 22 1 4 Status Indicators 14 22 2 Operation of Codepads in Partitioning 14 22 3 Arm Disarm all Areas at the Same Time 15 23 0 Remote Arming By Tel...

Страница 4: ...dicators 7 Table 8 Arming Methods 7 Table 9 How to Arm the System in AWAY Mode 8 Table 10 How to Arm the System in STAY Mode 1 8 Table 11 Fault Indicators 11 Table 12 Output Devices On Off 12 Table 13 Codepad ID and Buzzer Tone Change 14 Table 14 Domestic Dialling Telephone Digits 16 Table 15 Zone Status Display Descriptions 17 Table 16 System Status 17 Table 17 PET Pager Messages 19 Table 18 Exam...

Страница 5: ...d to meet all requirements quickly and easily 2 0 Specifications Table 1 Specifications Temperature Range 0o C to 45o C 32o F to 113o F Humidity 10 to 95 Power Source TF008 Plug Pack 240 V 18 V AC 1 3 A Stand By Current 65 mA Current Draw In Alarm Condition 115 mA Current Draw In Alarm Condition With Codepad 105 mA Back Up Battery 7 Ah 12 V DC rechargeable sealed lead acid battery Dimensions case ...

Страница 6: ...hing Slow 1 sec on 1 sec off Zone is manually isolated or selected to be isolated 3 2 AWAY Indicator The AWAY indicator shows the system is armed in AWAY Mode The AWAY indicator also flashes in unison with the STAY indicator when programming various options throughout the Operator s Manual See Section 4 2 Arming in AWAY Mode for information on the different methods of arming the system in AWAY Mod...

Страница 7: ...zer Table 7 Audible Indicators Audible Indicator Definition Once short beep A button was pressed on the codepad or end of exit time when armed in STAY Mode 1 or STAY Mode 2 Two short beeps The system accepted your code Three short beeps The requested function was executed One long beep Indicates the end of exit time when armed in AWAY Mode or the requested operation was denied or aborted One beep ...

Страница 8: ... STAY Mode 1 is programmed and a zone not automatically isolated is triggered the codepad beeps twice a second until the entry timer expires or the system is disarmed If the alarm condition is not reset by entering your user code followed by the button such as 2 5 8 0 before the entry timer expires the sirens activate into alarm Only your installer can program this feature Table 10 How to Arm the ...

Страница 9: ...indicator displays indicating a previous alarm on that zone How to Disarm the System Enter your user code followed by the button for example 2 5 8 0 Two beeps are heard 6 0 Adding User Codes Only the master code holder can add or change other system user codes including two auxiliary codes and the master code The master code is factory default is User 1 however multiple user codes can be assigned ...

Страница 10: ...our installer if you want to disable the ability to activate the codepad fire alarm or if you want to silence the codepad fire alarm 11 0 Codepad Medical Alarm Version 1 37 only An audible alarm activates when both the 7 and 9 buttons are pressed simultaneously Contact your installer to disable the ability to activate the codepad medical alarm or to silence the codepad medical alarm 12 0 Codepad T...

Страница 11: ...the disarmed state 14 0 Fault Analysis Mode If a fault occurs the FAULT or MAINS indicators flash and the codepad beeps once every minute If the AC mains supply failed the MAINS indicator flashes until the AC mains supply is restored Pressing the button once acknowledges the fault and stops the codepad from beeping once every minute How to Determine the Type of System Fault To determine which syst...

Страница 12: ...c test reports automatic arming and history events to operate correctly How to Program the Date and Time 1 Enter your four character master code followed by 6 and the button for example 2 5 8 0 6 Three beeps are heard and the STAY and AWAY indicators flashes 2 Enter the day month year hour and minute DD MM YY HH MM format for example DD day of the month MM month of the year YY current year HH hour...

Страница 13: ...ecall Use this function to replay back the last 40 events that occurred to the system The event memory history replays all alarms and arming disarming of the system in AWAY Mode STAY Mode 1 and STAY Mode 2 However the system cannot differentiate between arming the system in STAY Mode 1 or STAY Mode 2 How to Enter Event Memory Enter your four digit master code followed by 3 and the button for examp...

Страница 14: ...ot displayed that area is disarmed 22 1 3 Area Display Indicators The group of four AREA DISPLAY indicators show which area the zones displayed belong to All functions entered at the keypad only affect the area the keypad displays in the AREA DISPLAY Press the key to toggle between each area 22 1 4 Status Indicators A group of four indicators display the following AUX Indicator Displays when the c...

Страница 15: ...e pressing the button Two beeps are heard to indicate that the system is armed in AWAY Mode 3 Hang up the telephone and the system remains armed If your installer programs answering machine bypass call the control panel twice to make a connection with the system For example call the telephone number your control panel is connected to and let the call ring no more than four rings Hang up the teleph...

Страница 16: ...umbers 1 Enter your four character master code followed by 2 and the button for example 2 5 8 0 2 Three beeps are heard and the STAY and AWAY indicators flash If there are telephone numbers already programmed they are displayed one digit at a time by the codepad indicators If there are no telephone numbers programmed two more beeps are heard after entering this mode These two beeps are normally he...

Страница 17: ...g This feature is only applicable if your system is reporting to a pocket pager Basic pager reporting requires some interpretation of the numbers that appear on the display It is possible to differentiate between 1000 different systems when a number of control panels are reporting to the one pocket pager 27 1 Basic Pager Display Information Subscriber ID Number This is the identification number of...

Страница 18: ...8 Armed 9 Normal 0 Panic Duress 1 Fire Alarm 2 Medical Alarm 3 AC Normal 0 AC Failure 1 System Normal 0 System Fault 1 678 01200000 9000 1 2 3 4 5 6 8 7 1 2 3 1 Subscriber ID Number 2 Zone Status 3 System Status Figure 8 shows the transmission came from the control panel with an ID number of 678 and that zone 2 is in alarm The figure also displays that zone 3 was manually isolated and the system a...

Страница 19: ...lose User System Is Disarmed Open User Codepad Duress Duress Open User Low Battery Low Battery Low Battery Restore Battery Restore Codepad Panic Alarm Panic Codepad Fire Alarm V1 37 Fire Codepad Medical Alarm V1 37 Medical Test Report Test Zone Automatically Isolated When Armed Bypass Zone Disarming When Zone Has Been Isolated Bypass Restore Zone Zone Unsealed At End Of Exit Time Trouble Zone Zone...

Страница 20: ...ectors photoelectric beams reed switches and vibration sensors Disarmed Your system is in a state that does not accept alarms except on zones programmed for 24 hr operation Dynamic Battery Testing A feature used to monitor and test the condition of your back up battery Entry Time Entry Delay The time allowed after entering your premises by a zone programmed for delayed operation so that you can di...

Страница 21: ...station without sounding the sirens STAY Mode 1 A condition that automatically isolates zones when your system is armed in STAY Mode 1 Only your installer can program zones to be isolated automatically in STAY Mode 1 STAY Mode 2 A condition that automatically isolates zone when your system is armed in STAY Mode 2 Only the master code holder can program zones to be isolated automatically in STAY Mo...

Страница 22: ...30 0 Installation Notes EN 22 Bosch Security Systems 6 04 920036O OG 162 30 0 Installation Notes Installation Company Technician s Name Technician s Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes ...

Страница 23: ...Description Describe each zone and mark which zones were programmed to be automatically isolated in STAY Mode 1 or were programmed for day alarm operation Isolated In STAY Mode 1 Day Alarm Enabled Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 ...

Страница 24: ... Code 18 User Code 3 User Code 19 User Code 4 User Code 20 User Code 5 User Code 21 User Code 6 User Code 22 User Code 7 User Code 23 User Code 8 User Code 24 User Code 9 User Code 25 User Code 10 User Code 26 User Code 11 User Code 27 User Code 12 User Code 28 User Code 13 User Code 29 User Code 14 User Code 30 User Code 15 User Code 31 User Code 16 User Code 32 Auxiliary 1 User 33 Auxiliary 2 Us...

Страница 25: ...Arming YES NO Single Button Disarming STAY Mode YES NO Remote Arming By Telephone YES NO Automatic Arm in AWAY Mode YES NO Automatic Arming STAY Mode YES NO Automatic Arming Warning Time Minutes Automatic Arming Time AM PM Automatic Disarming Time AM PM Output Descriptions Output 1 Output 8 Output 2 Output 9 Output 3 Output 10 Output 4 Output 11 Output 5 Output 12 Output 6 Output 13 Output 7 Outpu...

Страница 26: ... Panel Account Number Domestic Reporting YES NO Domestic Reporting No Of Beeps Basic Pager Reporting YES NO PET Pager SMS Reporting YES NO Remote Arming Allowed YES NO DTMF Command Module Fitted YES NO Other System Information Siren Run Time Minutes Sensor Watch Interval In Days Can Your System Be Serviced By Another Technician YES NO If Yes Installer s Code ...

Страница 27: ...munication Fail 11 D Date and Time 10 11 Day Alarm 12 Deleting User Codes 8 Detectors 19 Disarmed 19 Disarming 8 Domestic Dialling 15 Acknowledging Domestic Calls 15 Disable 15 Programming Domestic Telephone Numbers 15 Duress Alarm 9 E E2 Fault 10 Entry Delay Entry Time 19 Entry Guard Timer 7 Event Memory Recall 12 Exit Time 19 External Equipment 19 F Fault Analysis 10 Fault Description Battery Fa...

Страница 28: ...epad Operations 13 Zone Indicators 13 Phone Controller 20 R Remote Arming By Telephone 14 Remote Control 19 S Sealed 20 Sensor Watch 10 20 Silent Alarm 20 Specifications 4 STAY Indicator 5 STAY Mode 1 7 20 Entry Guard Timer 7 STAY Mode 2 7 20 Entry Guard Timer 7 Programming Zones 8 Strobe Test 12 System Disarmed 5 T Tamper Alarm 9 Telco Arm Sequence 20 Telco Disarm Sequence 20 Telephone Line Fail ...

Страница 29: ...CC880 LP880 SC8016 Operators Guide Index EN 29 Bosch Security Systems 6 04 920036O OG 162 Notes ...

Страница 30: ...CC880 LP880 SC8016 Operators Guide Index EN 30 Bosch Security Systems 6 04 920036O OG 162 Notes ...

Страница 31: ...CC880 LP880 SC8016 Operators Guide Index EN 31 Bosch Security Systems 6 04 920036O OG 162 Notes ...

Страница 32: ... 2003 Bosch Security Systems 920036O 4998152460B Issue 1 62 Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 ...

Отзывы: