Bosch Solar Module c-Si M 60 EU I Bosch Solar Module c-Si M 60 S EU I Bosch Solar Module c-Si P 60 EU I Bosch Solar Module c-Si M 48 EU I Bosch Solar Module c-Si M 48 S EU 
Module manufacturer code 14, 17, 23

  

      

Bosch Solar Energy AG

 Circuitry guidelines | Electrical connection | 9

5 Circuitry guidelines

You may only interconnect identical solar modules of the 
same type and the same power class. Ensure that the 
maximum permissible system voltage is not exceeded 
when you connect the modules in series. In doing so, take 
into account the effect of variations in temperature on the 
voltage in solar modules, particularly since module voltage 
increases at low temperatures.  

 When connecting modules in parallel, make sure that each 
line connected in parallel contains the same number of 
modules and that suitable measures are in place to protect 
against power surges (e.g. line fuse). Make certain that the 
indicated load capacity regarding the reverse current I

R

, as 

stated in the datasheet, is not exceeded. 

A PV module may supply a higher current and/or a higher 
voltage under normal conditions than under standar-
dized test conditions. As a result the Isc and Uoc values 
on the module should be multiplied by a safety factor of 
1.25 to determine the rated voltages of components, the 
rated current in cables, the sizes of fuses and sizing of 
controls which are connected to the output of the PV 
modules. Ensure that you comply with local applicable 
standards and regulations.

6 Electrical connection 

The solar modules are designed for use in grid-connect-
ed solar generators. If they are used for any other pur-
poses, differing technical features should be taken into 
account. Solar modules may only be installed by quali-
fied specialists. In the process, they must comply with 
the relevant industrial standards and regulations for PV 
systems, such as the German Association for Electrical, 
Electronic & Information Technologies regulations, DIN 
standards, German Association of Energy and Water 
Industries guidelines, the network operator's technical 
connection conditions and employers' liability insurance 
associations' accident prevention rules. We draw your 
attention again to the following points in particular:  

  Only install non-damaged modules with clean, dry 

cabling, plug connectors and junction boxes. 

  The solar modules, particularly the plug connectors 

and tools, must remain dry during installation.

  Disconnection devices must be fitted between the 

module and inverter. The disconnect component 
must be readily accessible in order to disconnect the 
direct current side if danger should arise. 

 

Make sure that all electrical connections are properly 
secured.

  Only use cabling which is suitable for outdoor instal-

lation to interconnect module strings (UV and ozone-
resistant, temperature resistance at least between 
- 40° C and 110° C).

  Cables must feature a minimum cross-section of 

4 mm² and isolation must be approved for the maxi-
mum system open-circuit voltage.

  Protect cabling against damage by such means as 

suitable fastening with cable clips. 

Important note! 

Important note! 
Connecting cables which are able to 
move can lead to chafed points, thus 
causing insulation damage to the con-
necting cable. 

  The cables must be laid in such a way that the cables 

are not squashed or put under pressure in any other 
way.

  You must not open the junction box with pre-assem-

bled, connected cables. 

  The junction box, cabling and connection plug must 

not be cleaned or dampened with substances con-
taining grease or alcohol.

  Solar plugs pre-fitted in the factory must not be 

removed.

  Ensure that the module connection cable is relieved 

of strain when installed.

Содержание c-Si M 60 S EU

Страница 1: ... I Bosch Solar Module c Si M60 S I Bosch Solar Module c Si P60 Robert Bosch GmbH Australia Operating instructions for products with module manufacturer code 14 17 23 Issue 08 2013 Installation and Operation Guide Crystalline Solar Modules Bosch Solar Module c Si M 60 EU ...

Страница 2: ...l warranty and guarantee claims towards us shall lapse We reserve the right to update the information in this guide without prior notice The installation setup and commissioning of solar mod ules requires a high level of expertise and experience and therefore must be performed solely by specialists e g a specialist electrician who can verify the successful com pletion of suitable training 1 Introd...

Страница 3: ...er than 120V Even when the light intensity is low one must reckon with the full atrest voltage of the modules that is to Important notice say in the course of setup one must always exercise the greatest caution with regard to electrical faults e g short circuits The separation of conductors which carry direct cur rent can lead to light arcs Therefore prior to perform ing any work on the solar syst...

Страница 4: ...cleaning the angle of inclination must amount to at least 10 For optimized selfcleaning a 15 minimum angle of inclination is recommended Always ensure that the reverse side of the module is well ventilated Attention Due to heat accumulation under the modules there is an increased fire hazard associated with rooftop installations which do not meet the aforementioned requirements You should mount th...

Страница 5: ...rrosion between the solar module and substructure is prevented when different materials are used Fasten the solar modules in such a way that they are able to withstand all anticipated loads and any impacts caused by weather conditions Use only corrosion resistant screws to install modules Ensure the support structure does not allow rainwater or condensation water to reach the cable screw con necti...

Страница 6: ...r Energy AG 6 Installation guidelines pressure load rating 2400 Pa pressure load rating 5400 Pa without central support with central support screw fasten ing to assem bly holes fastener clamp system on long sides fastener clamp system on short sides slide in or lay in system slide in or lay in system table 2 vertical fastening area 500 500 360 440 360 440 400 200 400 300 300 central support clamp ...

Страница 7: ...olar Energy AG Installation guidelines 7 table 3 horizontal fastening area central support clamp section junction box pressure load rating 2400 Pa pressure load rating 5400 Pa without central support with central support screw fasten ing to assem bly holes fastener clamp system on long sides fastener clamp system on short sides slide in or lay in system slide in or lay in system 500 500 300 300 40...

Страница 8: ...3mm and have a surface area of at least 2mm width When fastening modules in the area of the module or drainage corners the following should be observed If corner clamps are used a minimum cover area of 28mm of the clamp must be ensured length of the assembly clamp The assembly clamp must overlie by min 8mm and max 12mm on the frame depth of assembly clamp figure 2 reverse side c Si M 60 and M 60 S...

Страница 9: ...uali fied specialists In the process they must comply with the relevant industrial standards and regulations for PV systems such as the German Association for Electrical Electronic Information Technologies regulations DIN standards German Association of Energy and Water Industries guidelines the network operator s technical connection conditions and employers liability insurance associations accid...

Страница 10: ...ures 7 Grounding Important notice Earthing Grounding Requirements In accordance with AS NZS 5033 clause 4 4 2 2 PV mo dules and mounting frame earth connections are to be a purpose made fitting providing earthing or bonding connections or purpose made penetrating washers or equivalent between the PV modules and mounting frame for the connection of dissimilar metals purpose made fittings are instal...

Страница 11: ...rd of organic material e g dry grass hay combustion in the vicinity of the system Avoid bending during transport or when unpacking Do not drop the modules Do not place any objects on the modules Do not handle the modules using sharp objects In the course of storage and transport it must be ensured that each solar module is sufficiently rein forced The stacking of packaging units can cause damage t...

Страница 12: ...de Bosch Solar Energy AG Robert Bosch Straße 1 99310 Arnstadt Germany Tel 49 0 3628 66 44 0 Fax 49 0 3628 66 44 1133 www bosch solarenergy com ...

Отзывы: