![Bosch AXT Rapid 180 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/bosch/axt-rapid-180/axt-rapid-180_operating-instructions-manual_47473016.webp)
EURO • BA F016 L69 923 • AXT RAPID 180/200 • GB • OSW 03.06
English - 5
The following table gives checks and actions that you can perform if your machine does not operate correctly.
If these do not identify/remedy the problem, contact your service agent.
Warning: Switch off and remove plug from mains before investigating fault.
Fault Finding
Symptom
Possible Cause
Remedy
Machine fails to operate
Switch fails to operate
Securing knob
3
has not been fully
tightened
Power turned off
Mains socket faulty
Extension cable damaged
Fuse faulty/blown
Motor protector has activated
Power supply interrupted
Follow “Restart Protection” procedure
Tighten securing knob
3
Turn power on
Use another socket
Inspect cable, replace if damaged
Replace fuse/restart
Follow “Overload Protection” proce-
dure
Follow “Overload Protection” proce-
dure
Machine functions
intermittently
Extension cable damaged
Machines internal wiring damaged
Motor protector has activated
Inspect cable, replace if damaged
Contact Service Agent
Follow “Overload Protection” proce-
dure
Poor cutting performance Cutting blade blunt
Cutting blade dirty
Feed intake or discharge chute
blocked
Replace blade (see “Blade Mainte-
nance”)
Remove blade and clean (see “Blade
Maintenance”)
Clean machine (see “Removing
Blockage”) and empty collecting bag
Cutting blade not rotating Cutting blade obstructed
Blade nut/bolt loose
Clear obstruction (see “Removing
blockage”)
Tighten blade nut/bolt
Excessive vibration/
noise
Blade nut/bolt loose
Cutting blade damaged
Machine damaged internally
Tighten blade nut/bolt
Replace blade
Contact Service Agent
F 016 L69 923 - GB Seite 5 Mittwoch, 18. Juni 2003 2:57 14
16 • F 016 L69 923 • TMS • 13.06.03