ARD-FPBEW2-H3 Fingerprint Reader, Multiclass
Installation | en
17
Bosch Access Systems GmbH
Installation manual
2022-06 | v01 |
3.5
RS485 connection
Control device
14 - 485 TRXN (RxTx-)
15 - 485 TRXP (RxTx+)
16 - 485 GND
Yellow (Black stripe)
Blue (White stripe)
White (Black stripe)
3.6
Resetting network settings
1.
Turn the power on.
2.
Press the network reset button on the rear of device until the device restart
automatically.
3.
Connect the device with default values.
–
TCP/IP address: DHCP address assignment (If DHCP address assignment is fails,
169.254.x.x will be set.)
–
Server mode: Disabled
–
RS-485: PC connection, 115200 bps
4.
Change the TCP/IP address or RS-485 information.
5.
Turn the power off later on and then check the network setting is properly.
3.7
Restoring the factory defaults
This will delete all data and root certificate on the device and reset the settings.
1.
Turn the power on.
2.
Press the reset button three times quickly.
3.
When the yellow LED is blinking, press the reset button again.
NOTE
–
If there is no root certificate on the device, you cannot restore the factory defaults.