background image

ARD-AYCE65B

Reader Functionality | en

19

Bosch Sicherheitssysteme GmbH

Installation manual

  | V 1.1 | 2009.08

5.3.7

Option No. 7: Single Key, 3x4 Matrix Keypad (ARD-

MDP64)

This unique mode is intended to let the host controller scan the 
ARD-AYCE65B keypad while still keeping the proximity card 
readers 26-Bit Wiegand or Clock & Data formats active.
An optional interface board must be used between the ARD-
AYCE65B and the host system. Each key press is immediately 
sent on DATA0 as an ASCII character at a baud rate of 9600 bits 
per second.
When a key is pressed DATA1 is pulled "low" until the key is 
released at which point DATA1 will be set to "high". This allows 
the controller to detect the duration of the key press.
The ARD-MDP64 interface unit outputs the data received to 7 
outputs emulating a keyboard. The interface unit will not affect 
any data that it receives from the proximity reader whether it is 
26-Bit Wiegand or Clock & Data.
Key pressed = ASCII Value

5.3.8

Option No. 8: 1 to 8 Keys BCD, Clock & Data

Buffers up to 8 keys and outputs keypad data without a facility 
code like standard Clock and Data card output.
The keypad PIN code can be one to eight digits long. The PIN 
code length is selected while programming the reader for 
Option 8. The reader will transmit the data when it receives the 
last key press of the PIN code. The data is sent across the two 
data output lines as binary data in Clock & Data format. 
If the ? key or the # key are pressed during PIN code entry, the 
keypad will clear the PIN code entry buffer, generate a beep 
and is ready to receive a new keypad PIN code.

0 = '0' ( 0x30 hex )

6 = '6' ( 0x36 hex )

1 = '1' ( 0x31 hex )

7 = '7' ( 0x37 hex )

2 = '2' ( 0x32 hex )

8 = '8' ( 0x38 hex )

3 = '3' ( 0x33 hex )

9 = '9' ( 0x39 hex )

4 = '4' ( 0x34 hex )

? = '*' ( 0x2A hex )

5 = '5' ( 0x35 hex )

# = '#' ( 0x23 hex )

Содержание ARD-AYCE65B

Страница 1: ...ARD AYCE65B RFID Proximity Card Reader en Installation manual ...

Страница 2: ......

Страница 3: ... 2 Single Key 6 Bit Wiegand Nibble and Parities 15 5 3 3 Option No 3 Single Key 8 Bit Wiegand Nibbles Complemented 16 5 3 4 Option No 4 4 Keys Binary Facility Code 26 Bit Wiegand 16 5 3 5 Option No 5 1 to 5 Keys Facility Code 26 Bit Wiegand 17 5 3 6 Option No 6 6 Keys BCD and parity bits 26 Bit Wiegand 18 5 3 7 Option No 7 Single Key 3x4 Matrix Keypad ARD MDP64 19 5 3 8 Option No 8 1 to 8 Keys BCD...

Страница 4: ...4 en Table of Contents ARD AYCE65B V 1 1 2009 08 Installation manual Bosch Sicherheitssysteme GmbH 6 Appendix 25 6 1 LED displays 25 6 2 Technical Support 27 ...

Страница 5: ...ader The unit is vandal resistant and water resistant suitable for indoor or outdoor mounting This manual contains the following information Installation Wiring instructions Operation Instructions 1 2 Box Content Before beginning verify that all of the following is in the box If anything is missing please report the discrepancy to your nearest Bosch office One ARD AYCE65B unit Installation kit Ins...

Страница 6: ...rrent Cable distance to host controller Up to 500ft 150 meters using an 18AWG cable Max proximity card read range 40mm 1 575 inch Proximity card modulation ASK at 125 KHz Proximity card compatibility EM cards Card Transmit format Reader 26 bit Wiegand or Clock Data Keypad Transmit Format Reader Programmable PIN code formats LED indicators Two tri colored LEDs Communication Data1 Clock Data0 Data T...

Страница 7: ...mable Patented Blue backlit keypad Optical back tamper sensor and open collector tamper output Internal buzzer provides audible interface feedback Two status programming Interface LEDs tri colored Fully potted construction for outdoor use Comes with mounting template for easier installation Comes with an installation kit that includes a security screw and a security screw tool Reader Programmable ...

Страница 8: ...be at shoulder height For wall mounting use the included mounting template as a guide for drilling holes for mounting screws and wiring For US Gang Box mounting no drilling is necessary Figure 3 1 Drilling Mounting Template Route the interface cable from the ARD AYCE65B to the controller A linear type power supply is recommended Screw the ARD AYCE65B to its mounting location or US gang box ...

Страница 9: ...by cutting the cable jacket back 1 inches and strip the wire inch Splice the unit s pigtail wires to the corresponding controller wires and cover each connection Refer to the wire color table below and to the wiring diagram provided on the following page If the tamper output is used connect the purple wire to the correct input on the controller Trim and cover all unused conductors Reader Color Fun...

Страница 10: ... coded according the Wiegand standard When using a separate Power Supply for the Reader this Power Supply and that of the Controller must have a common ground The Reader s cable shield wire should preferably be attached to an earth ground or a signal ground connection at the panel or power supply end of the cable This configuration is best for shielding the Reader cable from external interference ...

Страница 11: ...t Keypad Transmission Formats For more information see Selecting Keypad Transmission Format on page 13 Proximity Cards presented to the reader are always sent in either 26 Bit Wiegand Clock Data or Wiegand Card PIN format See Selecting Proximity Card Transmission Format on page 20 for more information 5 2 Programming the ARD AYCE65B Series Programming the ARD AYCE65B series is done solely via the ...

Страница 12: ...Key 8 Bit Wiegand Nibbles Complemented 4 Keys Binary Facility Code 26 Bit Wiegand 1 to 5 Keys Facility Code 26 Bit Wiegand 6 Keys BCD and Parity Bits 26 Bit Wiegand Single Key 3x4 Matrix Keypad 1 to 8 Keys BCD Clock Data 2 Selecting Card Transmission Format 26 Bit Wiegand Clock Data Wiegand Card PIN 3 Changing the Programming Code 1234 4 Changing the Facility Code 0 6 Backlight Options Off On Defa...

Страница 13: ...ed 2 This indicates that the ARD AYCE65B has returned to Transmit Mode 3 Wrong entries may reset the reader back to Transmit Mode While in Programming Mode if no key is pressed for 30 seconds the ARD AYCE65B will exit Programming Mode and return to Transmit Mode 5 3 Selecting Keypad Transmission Format The ARD AYCE65B has eight different keypad transmission formats to select from Follow the steps ...

Страница 14: ...Keypad Transmission Format Option Number See the table below to determine the Option Number for the Keypad Transmission Format you wish to select NOTICE Only one keypad transmission format can be active at any one time When using the keypad transmission format 1 to 8 keys BCD Clock Data Option 8 an additional input is required to specify the number of keys in the PIN code Keypad Transmission Forma...

Страница 15: ... 4 bits with 2 parity bits added Even parity for the first 3 bits and odd parity for the last 3 bits Hexadecimal 5 3 2 Option No 2 Single Key 6 Bit Wiegand Nibble and Parities Each key press immediately sends 4 bits with 2 parity bits added Even parity for the first 3 bits and odd parity for the last 3 bits Hexadecimal 0 110100 A 6 101100 1 000010 7 101111 2 000100 8 110001 3 000111 9 110010 4 101...

Страница 16: ...lity code is 000 See changing the Facility Code on page 22 for more information The keypad PIN code is 4 digit long and can range between 0000 and 9999 On the fourth key press of the 4 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card If the key or the key are pressed during PIN code entry the keypad will clear the PIN code entry buffe...

Страница 17: ...o signify the end of PIN code entry For keypad PIN codes that are 5 digits long on the fifth key press of the 5 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card If the key is pressed during PIN code entry or a PIN code greater than 65 535 is entered the keypad will clear the PIN code entry buffer generate a beep and is ready to receiv...

Страница 18: ...the Wiegand Data lines as a BCD message If the entry of the 6 digit keypad PIN code is disrupted and no number key is pressed within 5 seconds the keypad will clear the PIN code entry buffer generate a medium length beep and is ready to receive a new 6 digit keypad PIN code EP AAAA BBBB CCCC DDDD EEEE FFFF OP Where EP Even parity for first 12 bits OP Odd parity for last 12 bits F 8 Bit Facility Co...

Страница 19: ...d to 7 outputs emulating a keyboard The interface unit will not affect any data that it receives from the proximity reader whether it is 26 Bit Wiegand or Clock Data Key pressed ASCII Value 5 3 8 Option No 8 1 to 8 Keys BCD Clock Data Buffers up to 8 keys and outputs keypad data without a facility code like standard Clock and Data card output The keypad PIN code can be one to eight digits long The...

Страница 20: ...that you wish to use 1 Enter Programming Mode 2 Press 2 to enter Menu 2 The Transmit LED will turn red 3 Enter the appropriate option number for the proxy card transmission format that you wish to select options below If an incorrect option is entered the reader will return to Transmit Mode and the keypad transmission format will remain unchanged 4 System returns to Transmit Mode You will hear thr...

Страница 21: ...ode entry buffer generate a medium length beep and be ready to receive a new card The keypad PIN code can be one to five digits long in the range of 0 to 99 999 When entering a keypad PIN code the key must be pressed to signify the end of the PIN entry When pressing the key press the data is sent by the Wiegand data lines If the key is pressed the keypad will clear the card buffer and the PIN code...

Страница 22: ...t LED will turn red 3 Enter the new 4 digit code you wish to set as the Programming Code 4 System returns to Transmit Mode You will hear three beeps The Program LED will turn off The Transmit LED will turn red B Second key entered E Fifth key entered C Third key entered EP Even parity for first 12 bits OP Odd parity for last 12 bits A First key entered B Second key entered NOTICE Programming Code ...

Страница 23: ...urn off The Transmit LED will turn red 5 8 Setting the Backlight 1 Enter Programming Mode 2 Press 6 to enter menu 6 The Transmit LED will turn red 3 Enter the appropriate option number for the backlight option that you wish to select 0 for always off 1 for always on 2 for 10 sec backlight after a key is pressed otherwise off 3 for 10 sec backlight after a key is pressed otherwise dimmed 4 System r...

Страница 24: ...hear a long beep and the controller will return to Normal Mode without erasing the memory of the controller 5 10 Replacing a Lost Programming Code In the event that the Programming Code is forgotten the ARD AYCE65B may be reprogrammed in the field using the following instructions 1 Remove power from the reader 2 Activate tamper by removing the reader from the wall or removing the reader s case 3 A...

Страница 25: ... the key 2 Enter the 4 digit programming code red green Exiting programming mode Press red and a beep Selecting keypad transmission format 1 Enter programming mode 2 Press 1 3 Enter the no for the keypad transmission format 4 Back to transmit mode red red green green and three beeps Selecting Proximity Card transmission format 1 Enter programming mode 2 Press 2 3 Enter the no for the prxy card tra...

Страница 26: ...new 3 digit code 4 Back to transmit mode red red green green and three beeps Setting the backlight 1 Enter programming mode 2 Press 6 3 Enter the no for the backlight option 4 Back to transmit mode red red green green and three beeps Return to Factory Default Settings 1 Enter programming mode 2 Press 0 3 Enter the 4 digit programming code 4 Back to transmit mode flash red three beeps red green fla...

Страница 27: ...rlands Phone 31 0 402783955 Fax 31 0 402786668 emea securitysystems bosch com http www boschsecurity com Bosch Security Systems 130 Perinton Parkway Fairport New York 14450 USA Phone 1 585 223 4060 Fax 1 800 289 0096 security sales us bosch com http www boschsecurity us Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch ...

Страница 28: ...28 en Appendix ARD AYCE65B V 1 1 2009 08 Installation manual Bosch Sicherheitssysteme GmbH ...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...Bosch Sicherheitssysteme GmbH Robert Koch Straße 100 D 85521 Ottobrunn Germany Telefon 49 89 6290 0 Fax 49 89 6290 1020 www boschsecurity com Bosch Sicherheitssysteme GmbH 2009 ...

Отзывы: