![Bosch Aquatak 1200 Plus Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/bosch/aquatak-1200-plus/aquatak-1200-plus_operating-instructions-manual_48306017.webp)
English - 5
Expose the strainer 14 in the machine water inlet
connection by removing the inlet connector 7.
Rinse and replace. If damaged replace.
Never use the pressure washer without the strainer
or a damaged strainer.
To move the machine use the top handle and roll the
machine on the wheels.
To transport the unit up or down steps or over obsta-
cles, it must be lifted by the top handle.
AQUATAK 1250
If the unit is to be stored or transported horizontally
the detergent tank should be drained first.
Clean the exterior of the machine thoroughly using a
soft brush or cloth. Do not use water, solvents or pol-
ishes. Remove all debris, especially from the venti-
lation slots.
Frost will damage a pressure washer that has not
been completely emptied of water. The machine
should be stored in a frost free room.
Do not place other objects on top of the machine.
The following table gives checks and actions that you can perform if your machine does not operate correctly.
If these do not identify/remedy the problem, contact your service agent.
Warning: Switch off and remove plug from mains before investigating fault.
Cleaning/inspecting the strainer
Transport
L
After use storage
Fault Finding
Symptom
Possible Cause
Remedy
Motor refuses to start
Plug not connected
Mains socket faulty
Fuse faulty/blown
Extension cable damaged
Motor protector has activated
Frozen
Connect plug
Use another socket
Replace fuse
Try without extension cable
Allow to cool for 5 minutes
Wait for pump/water supply hose/ac-
cessory to thaw
Motor stops
Fuse faulty/blown
Wrong mains voltage
Motor protector has activated
Replace fuse
Check that mains voltage corresponds
to specifications on the model tag
Allow to cool for 5 minutes
Fuses blow
Fuses faulty/blown
Change to a mains supply higher than
the pressure washer amp consumption
Excessive working pres-
sure
Nozzle partly blocked
Clean nozzle
Pressure pulsating
Air in the inlet water supply hose/pump
Inadequate water supply
Water strainer blocked
Water supply hoses squeezed
High pressure hose too long
Allow pressure washer to run with
open spray handle and nozzle at low
pressure until regular working pres-
sure is obtained.
Check that the water supply corre-
sponds to specifications. The minimum
specification for the water supply hose
is 1/2" or 13 mm diameter.
Clean water strainer
Straighten out kinked water supply
hoses
Dismount high pressure extension
hose. Retry (extension hose max. 7 m)
F016 L70 898.book Seite 5 Mittwoch, 25. Juli 2012 11:46 11
17 • F 016 L70 898 • 12.07