background image

25

6 720 606 601

LIMITED WARRANTY

Aquastar

General

Aquastar water heaters are warranted by the Manufacturer
(BOSCH)  through  Controlled  Energy  Corp.  Controlled
Energy  Corp.  (CEC)  will  furnish  a  replacement  heat
exchanger and will furnish a replacement of any other part
which fails in normal use and service within the applicable
periods  specified  below,  in  accordance  with  the  terms  of
this warranty. The CEC replacement will be warranted for
the unexpired portion of the original warranty. This warranty
will be valid only for water heaters in possession of the original
purchaser as recorded on the warranty card.

The heat exchanger

If the heat exchanger fails within twelve (12) years after the
original  installation  and  operation  CEC  will  furnish  a
replacement heat exchanger. However, if the water heater
is installed in other than a single family dwelling this heat
exchanger warranty is limited to two (2) years from date of
original installation and operation.

Exceptions

This warranty will not apply:

1.

to defects or malfunctions resulting from failure to properly
install,  operate  or  maintain  the  unit  in  accordance  with
the printed instructions provided;

2.

  to  damage  or  abuse,  accident,  neglect  or  freezing  and

other acts of nature;

3.

to damage resulting from operation with either the flame
sensor rod or overheat sensor removed;

4.

to  failure  of  the  heat  exchanger  resulting  from  the
operation of the water heater in a corrosive atmosphere
or at water temperatures exceeding the maximum rating,
or if the water heater is not supplied with potable water;

5.

to  defects  or  damage  cause  by  any  attachment
or modification, including any energy-saving device.

All other parts

If  any  other  part  fails  within  two  (2)  years  after  original
installation and operation, CEC will furnish a replacement
part free of charge.

Shipping costs

In addition to supplying the replacement part(s), CEC will
provide ground service delivery for these parts. Expedited or
upgraded shipping will be charged to the customer.

Service labor costs

This  warranty  does  not  cover  any  labor  costs  associated
with service, removal or re-installation of part(s).  All such
costs  must  be  borne  by  the  Purchaser.  Additionally,  this
warranty  does  not  cover  any  labor  costs  associated  with
service, removal or re-installation of the original water heater
or a replaced water heater.

NOTE : 

the water heater must be free of damaging scale

deposits and not subject to gas pressures greater than those
shown on the rating plate, which must not be altered, defaced
or removed.

How to Make a Claim

Any claim for warranty parts should be made to your local
dealer,  distributor  or  to  CEC.  If  CEC,  please  contact  the
Technical Support Department:

Controlled Energy Corp.
340 Mad River Park
Waitsfield, VT 05673
Phone:  800-642-3111
www.controlledenergy.com/tech

In most cases, the dealer or distributor will be able to promptly
honor your claim and subsequently notify CEC.  However,
all replacements are made subject to validation by CEC of
in-warranty coverage.  The damaged or defective item must
be made available in exchange for the replacement.

Miscellaneous

No one is authorized to make any other warranties on behalf
of  CEC.  It  is  expressly  understood  that  the  replacement
warranty  of  CEC  shall  be  in  lieu  of  any  and  all  other
warranties,  express  or  implied,  including  warranties  of
merchantability  or  fitness  for  a  particular  use  or  purpose,
and  further  that  CEC  shall  not  be  liable  for  any  loss  or
damage directly or indirectly arising from the use of the hot
water heater, or for any consequential damages arising from
such use (including damages from water leakage). CEC’s
sole  liability  with  respect  to  any  defect  shall  be  for  the
replacement  of  the  defective  part(s).  Some  states  do  not
allow such limitations and exclusions, so the above may not
apply to you.
This warranty gives specific legal rights. You may also have
other rights which vary from state to state.

Содержание AquaStar 125FX LP

Страница 1: ...result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable combustible or corrosive vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Close gas valve Open windows Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas...

Страница 2: ...r When the hot water faucet is shut off the gas valve automatically closes and the burners turn off followed immediately by the exhaust system Your hot water faucet is an ignition key to turn on the water heater giving you control over your hot water energy use Every time you turn off your hot water faucet the energy consumption for hot water returns to zero FEATURES Electronic Pilot Ignition On O...

Страница 3: ...R ALCOVE OR CLOSET INSTALLATIONS FRONT VIEW SIDE VIEW AQUASTAR MODEL 125FX On a combustible wall surface the unit should be mounted away from the wall to provide adequate clearance of the vent pipe See page 5 for instructions TOP A 12 FRONT B 4 BACK 0 SIDES 4 FLOOR C 12 VENT DIAMETER 4 MODEL 125FX ...

Страница 4: ...he location of your new heater For your safety and for proper heater operation you must provide an abundant supply of combustion air and a proper venting installation The heater may still operate even when improperly vented It will however be less efficient and could eventually damage the heater It could even result in human sickness or death due to oxygen deprivation and carbon monoxide poisoning...

Страница 5: ...pace must be provided with two permanent openings one commencing within 12 inches of the top and one commencing within 12 inches of the bottom of the enclosure Each opening must have a minimum free area of one square inch per 1000 Btu hr if all air is taken from inside the building 2000 Btu hr if all air is taken from the outside by horizontal ducts 4000 Btu hr if all air is taken from the outside...

Страница 6: ...a pair of studs and then the heater should be attached to the support boards See Fig 2 NOTE Additionally the 125FX should be spaced away from any combustible wall surface to provide the necessary clearance that the venting material specifies must be maintained between the vent pipe and a combustible surface See VENTING section Also review the FXHOOD horizontal vent terminator instruction sheet pro...

Страница 7: ...45 degrees is considered an elbow Note Single wall pipe should not be used in concealed unoccupied or unheated locations Listed thimbles or collars are necessary to pass through wall partitions If the vent system passes through combustible areas where the vent clearance requirements cannot be maintained it is permissible to chase straight sections of sealed 4 inch single wall vent through 5 inch o...

Страница 8: ...to prevent negative air from freezing the Aquastar see Fig 5 for restrictions in location of vent terminal G181_274 Approved Vent Terminal FXHOOD or other approved terminal The FXHOOD is design approved with the Aquastar 125FX and has a built in back draft flapper to prevent negative air from freezing the Aquastar see Fig 5 for restrictions in location of vent terminal 4 single wall venting only U...

Страница 9: ...ngs and so that proper clearances are maintained See Fig 5 a The vent terminal shall not be less than 7 feet above a public walkway b The vent terminal shall terminate at least 3 feet above any mechanical air inlet within 10 feet c The vent terminal shall not be within a 6 foot radius from a gas meter or regulator d The vent terminal shall be a minimum of 6 feet from any combustion air inlet e The...

Страница 10: ...ulator to the inlet of the Aquastar regulator For semi rigid copper piping 5 8 up to 20 feet and 3 4 up to 50 feet distances For Black Iron piping 1 2 up to 30 feet and 3 4 up to 150 feet distances Flex line tubing is NOT recommended but if used then oversize it THESEFIGURESAREFORAQUASTARSUPPLYONLY ALL OTHER APPLIANCES IN THE BUILDING WILL NEED TO BE INCLUDED IN THE PIPE SIZING National Fuel Gas C...

Страница 11: ...ordinary number of fittings GAS LINE SIZING Nominal Iron Length of Black Iron Pipe Feet Pipe Internal Size Diameter inches inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200 1 4 0 364 32 22 18 15 14 12 11 11 10 9 8 8 7 6 3 8 0 493 72 49 40 34 30 27 25 23 22 21 18 17 15 14 1 2 0 622 132 92 73 63 56 50 46 43 40 38 34 31 28 26 3 4 0 824 278 190 152 130 115 105 96 90 84 79 72 64 59 55 1 1 049 520 3...

Страница 12: ...is to be used at this joint The flexible hot water outlet line is supplied attached to the heater Be certain there are no loose particles or dirt in the piping Blow out or flush the lines before connecting to the water heater Full port valves should be installed on both the cold water supply and hot water outlet lines to facilitate servicing the heater see Fig 7 For installation on a private well ...

Страница 13: ...e heater CAUTION Label all wires prior to disconnection when servicing controls Wiring error can cause improper and dangerous operation Verify proper operation after servicing The AquaStar 125FX requires an electrical power supply from 120VAC 60Hz circuit and must be properly grounded A means for switching off the 120 VAC power supply must be provided The heater is wired as shown in the wiring dia...

Страница 14: ...er and an automatic ignition control system 4 Set the ON OFF switch flip down cover plate on front panel strip marked to the position In this position the water heater is ready to use 5 Verify that the power supply to the appliance is turned on To operate the heater set the ON OFF switch to position The switch is located behind the flip down cover plate on the front panel strip To shut down the ga...

Страница 15: ...climate areas it might be necessary to set the control all the way clockwise to the right for maximum temperature rise Do not supply the AquaStar 125FX with preheated water For this type of application purchase a solar model 125 B LPS or 125 B NGS If the inlet water temperature to the water heater is very warm the heater can produce temperatures that may be found to be too hot A temperature balanc...

Страница 16: ...erature settings and the water has a high mineral content periodic descaling may be necessary The heating coils should be flushed with a descaling solution Consult your dealer or service person TROUBLE SHOOTING see maintenance table Introduction The AquaStar 125FX pilot and burners are ignited by a water flow valve Numerous water related problems can cause this water valve to malfunction such as I...

Страница 17: ... pilot light ignites At that point retighten the screw one and a half turns See Fig 14 5 Pilot electrovalve switch may need to be replaced see fig 9 Measure millivoltage at pilot electrovalve see Fig 9 6 Control Box may need to be replaced see fig 9 Check wire connections and test operation of control box see Fig 9 PILOT SPARKS CONTINUOUSLY WITH NO WATER RUNNING 1 Microswitch needs adjustment If n...

Страница 18: ... NO SPARK AT THE PILOT White vinegar should be applied first to any corrosion before the loosening of screws HOT WATER TEMPERATURE FLUCTUATES UNIT DEACTIVATED 1 Unbalanced pressure in waterlines The added restriction caused by the Aquastar in the hot water system can result in uneven pressures between the cold and the hot In such cases when mixing cold water at the tap the lower hot water pressure...

Страница 19: ...19 6 720 606 601 ...

Страница 20: ...20 6 720 606 601 ...

Страница 21: ...as pressure test nipple 4 Main gas burner 5 Pilot gas tubing 6 Gas valve 7 electric control box 8 Power cord 9 on off switch 10 Temperature adjustment selector 11 Microswitch 12 Gas inlet gas pressure test nipple 13 Exhaust Fan 14 Flexible hot outlet 5 11 1 4 9 10 12 2 6 8 7 13 3 14 6 720 606 601 12 1AL ...

Страница 22: ...22 6 720 606 601 Fig 16 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Страница 23: ...21 NG 16 Diaphragm switch 8 708 504 049 LPG 17 Pilot electrovalve 8 708 501 249 18 Burner electrovalve 8 708 501 250 19 Cold water pipe 8 700 705 627 20 Exhaust fan assembly 8 707 204 023 21 Exhaust fan cable 8 704 401 168 22 Outlet flex hose 8 700 703 139 23 Washer 8 700 103 658 24 Water valve 8 707 006 361 25 Water valve cover 8 705 500 101 26 Diaphragm 8 700 503 092 27 Water inlet filter 8 700 ...

Страница 24: ...24 6 720 606 601 Fig 17 Flow chart of Aquastar 125 FX ...

Страница 25: ...e replacement part s CEC will provide ground service delivery for these parts Expedited or upgraded shipping will be charged to the customer Service labor costs This warranty does not cover any labor costs associated with service removal or re installation of part s All such costs must be borne by the Purchaser Additionally this warranty does not cover any labor costs associated with service remov...

Страница 26: ...de Cacia 3801 856 Aveiro PORTUGAL 5 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V E S R A E Y 2 Y R E V E S R A E Y 5 3 Y R E V E E V L A V R E T A W E T A C I R B U L E V L A V R E T A W D L I U B E R N E E R C S R E T L I F R E T A W T C E P S N I Y L B M E S S A T O L I P T C E P S N I Y L B M E S S A T N E V T C E P S N I R E N R U B N I A M T C E P S N I Recycled paper 2004 ...

Отзывы: