E n g l i s h
28
ELECTRICAL CONNECTION
(continued)
WARNING: FIRE HAZARD - LOOSE
OR IMPROPER ELECTRICAL CONNEC-
TIONS CAN CAUSE FIRE. MAKE CER-
TAIN THAT ALL ELECTRICAL CONNEC-
TIONS ARE PROPERLY MADE.
• Do not pre-twist the wires before
connecting them with wire nuts.
• Extend the dishwasher’s stranded
wires 1/8” (3mm) beyond the power
supply cable’s solid wires, as shown in
Figure 28.
5) Using the supplied wire nuts,
connect the electrical supply wires to
the dishwasher’s wires, black to black,
white to white, and green or bare to
green or bare. Make certain that the
insulated wires show no bare wire from
the bottoms of the wire nuts. Gently tug
the wires to make certain they are
securely connected.
6) Press the wires into the junction box.
Make certain that the wire nuts do not
loosen.
7) Place the cover on the juction box
and secure it to the junction box with
the supplied screw.
DOOR TENSION ADJUSTMENT
(only
on SHI and SHV models)
After the dishwasher is installed, open
and close the door several times to
make sure that it does so with ease. If
the door closes too quickly or if the door
falls open, the spring tension needs to
be adjusted.
To Adjust the Spring Tension:
1) Obtain the provided Door Tension
Screws (Figure 1, letter K) from the SHI/
SHV parts bag.
2) Insert the screws as shown in
Figure 29. Turning the screw clockwise
increases the spring tension. Turning
the screws counter-clockwise
decreases the spring tension.
BASE AND TOE PANEL
Regular Toe Panel Installation
Use the toe panel screws (Figure 1,
letter D) from the Dishwasher Installa-
tion Kit and a Torx screwdriver to install
the toe panel as shown in Figure 30.
(Continued on next page)
Figure 29/Ilus. 29
Base and Toe Panel | Base et Panneau inférieur | Base y Panel de Pie
1/8”
Figure 28/Ilus. 28
3mm
Figure 30/Ilus. 30
Содержание Apexx SHY99A
Страница 34: ...56 02 05 68 50 8304 CS Part 584320 ...