en | Installation
AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12
Installation Manual
Bosch Sicherheitssysteme GmbH
Example
To set the date and time for the 25th of December 2010 at 10:30PM, enter:
[Installer CODE + 955][#] break until time is shown [1 0 1 2 2 5 2 2 3 0][#]
3.1.2
AMAX panel 2000 / AMAX panel 2000 EN Zone Defaults
The default zone settings for the control panel are listed in Table 3.1, Page 14. You can
program zones 1 to 8 to any of the zone types. Refer to Table 10.4, Page 82 for the zone type
you can select.
Table 3.1
Zone defaults
3.2
System Special Status Definition
–
When the AC power voltage is lower than 9V±5%, the system will not detect/send out the
zone status report to CMS.
–
When the AC power voltage is more than 9V±5%, the system will wait for 1 minute to
back up the normal work while in a stable work status.
3.3
Programming
The control panel programming options are stored in a non-volatile flash memory. This
memory has all relevant configurations and user-specific data even after a total power loss.
Because the data retention time is quite long without power, reprogramming is not required
after powering up the control panel.
You can change data as many times as required without any additional specialized equipment.
The memory is organized in locations, each of which holds the data for a specific function.
In general, the entire programming sequence consists of selecting the required location and
entering or changing the current data. Repeat this procedure until you program all the
required data.
The installer code turns active only when it’s enabled by a user. You cannot enter installer’s
programming mode if the system is armed, or during siren run time.
You can program the AMAX panel 2000 / AMAX panel 2000 EN using any of these three
devices:
–
Keypads
–
A - Link - Plus Upload/download software
–
CP-EZPK Programming key
3.3.1
Programming with the AMAX Keypad 2000
To program the control panel using the keypad, the system must be disarmed with no alarm
memory present and installer access must be enabled.
To access installer’s programming mode:
Zone
Zone type
Zone
Zone type
1
Delay
5
Instant
2
Follower
6
Instant
3
Instant
7
Instant
4
Instant
8
Instant
NOTICE!
0 is the minimum value and 15 is the maximum value that can be programmed into any
location.