manualshive.com logo in svg
background image

AMAX panel 2000 / AMAX panel 2000 EN

F.01U.249.500

en

User Guide

Содержание AMAX panel 2000 EN ICP-AMAX-P-EN

Страница 1: ...AMAX panel 2000 AMAX panel 2000 EN F 01U 249 500 en User Guide ...

Страница 2: ......

Страница 3: ... Disarming with wireless control Key 9 2 2 3 Disarming with Key switch 9 3 Faults or Tamper conditions 10 3 1 System fault or tamper analysis Mode 10 4 Walk test mode 12 5 Event Memory Recall mode 13 6 Reset the Control Panel 14 7 Bypassing 15 7 1 Bypassing Zones 15 7 2 Bypassing Faults and Tamper conditions Except Zone Tampers 15 8 Enable Disable the installers code 16 9 Change individual code 17...

Страница 4: ...Y arm code quick arming Disarming Disarm code Other Commands Fault and Tamper Analysis code 2 Walk test code 4 Event recall code 5 System Reset code 6 Bypassing zones code 9 zone Bypassing Faults and Tamper conditions code 97 Enable Disable Installer code Enable code 98 Disable code 98 Change individual code code 99 newcode Alarm Commands Duress alarm code 0 Emergency alarm Simultaneously press an...

Страница 5: ...sh 1 second lights on 1 second lights off Exit time Fast flash 0 25 seconds lights on 0 25 seconds lights off Programming mode or Code function mode STAY indicator flashes simultaneously STAY on System is armed in STAY mode off System not armed in STAY mode Slow flash 1 second lights on 1 second lights off Exit time Fast flash 0 25 seconds lights on 0 25 seconds lights off Programming mode or Code...

Страница 6: ... second beep The requested operation is refused Incorrect operation signal Two short beeps The system accepted the code The system executed the requested function One short beep per second In walk test mode One short beep every two seconds Exit time started Continued sound Last 10s on exit time Keypad fault tamper sound fault tamper to be acknowledged Keypad alarm sound Continuous 0 5 second beep ...

Страница 7: ...____________________________________ Code 2 _____________________________________________________ Code 3 _____________________________________________________ Code 4 _____________________________________________________ Code 5 _____________________________________________________ Code 6 _____________________________________________________ Code 7 ___________________________________________________...

Страница 8: ...t your installer to enable disable this function 2 1 1 2 Telephone remote arming The user dials the control panel number The control panel answers the call and issues a long beep After the long beep the user must press the key When the Panel receives the signal it will confirm the arming of the control panel with a high tone Please contact your installer to enable disable this function 2 1 1 3 Arm...

Страница 9: ...y isolated zones Interior Instant Zone begin to flash and continue until the exit time is finished To arm the system in STAY mode method 2 Press and hold for 3 seconds When two beeps sound release the button The STAY indicator flashes slow and exit time starts After exit time the STAY indicator is on Please contact your installer to enable disable this function 2 1 3 Forced arming Arming the syste...

Страница 10: ... determining a system fault or tamper condition 1 Enter your Code and 2 and press Two beeps sound The FAULT indicator remains lit and the STAY and AWAY indicators flash The lit zone indicators indicate the type of fault or tamper condition that occurred 2 For a multi level menu enter the corresponding number to enter the submenu press 0 key to return to the main menu 3 To exit from Fault and Tampe...

Страница 11: ... Fault 4 Bosch Option Bus Power Fault 5 RF Power Fault 3 Warning Device Failure List 1 Warning Device 1 Disconnected 2 Warning Device 1 Short 3 Warning Device 2 Disconnected 4 Warning Device 2 Short 4 Telephone Line Fail 5 Date and Time Fail 6 Communications failure 1 Communication Failure 1 2 Communication Failure 2 3 Communication Failure 3 4 Communication Failure 4 7 Tamper 1 On board Tamper 2 ...

Страница 12: ...tivating Walk test Mode bypass any zones that are not required for testing During the walk test no walk test report is sent out to the control panel system To enter into Walk test Mode 1 Enter your Code 4 and press Two beeps sound and the STAY and AWAY indicators flash The keypad beeps once per second when walk test mode is active 2 Unseal and seal the zones to be tested The keypad sounds one seco...

Страница 13: ...rse chronological orer Example If the events occurred in the following order The alarm memory is played back in this order Each event is indicated by a beep and a lit indicator Resetting a disarmed 24 Hour alarm is indicated by a beep only After the last event two beeps sound to indicate the end of the playback You can stop the replay at anytime by pressing If the system is armed in STAY mode the ...

Страница 14: ...ring and Business Solutions Limited 6 Reset the Control Panel This function allows code holders to reset all Alarm Faults and Tamper conditions Enter your code and then press 6 The keypad beeps twice and the signal is eliminated NOTICE You can reset alarms faults or tamper conditions only when they are not active anymore ...

Страница 15: ...zones please repeat step 2 3 If you wish to cancel bypassed zone enter the zone number of the bypassed zone then press the key If you wish to cancel several bypassed zones please repeat step 3 4 Press to exit 7 2 Bypassing Faults and Tamper conditions Except Zone Tampers Bypassing Faults and Tamper conditions one or more faults and tamper conditions are disabled for one arming cycle After bypassin...

Страница 16: ...s Solutions Limited 8 Enable Disable the installers code This function allows user code holder to enable or disable the installer code Installer can only perform actions when he is enabled by a user 1 Enter your user code 98 and press to enable the function Two beeps sound 2 Enter your user code 98 and press to disable the function Two beeps sound ...

Страница 17: ...nge the code 1 Enter your code and press 99 Two beeps sound and the STAY and AWAY indicators flash and your user number is shown on the keypad 2 Enter the new code and press Two beeps sound and the STAY and AWAY indicators are extinguished NOTICE Thia function is automatically terminated if you do not press a button within 240 seconds or if you press One long beep indicates that the code already e...

Страница 18: ...ess and hold 1 and 3 or simultaneously press and hold and a silent emergency alarm will be transmitted Please contact your installer to enable disable the keypad emergency alarm functionality Simultaneous pressing and holding the wireless remote control key arming and disarming key can also transmit a wireless emergency alarm 10 3 Keypad fire alarm If you simultaneously press and hold 4 and 6 a si...

Страница 19: ... control panel during an alarm Contact your installer to enable disable the Domestic dialinf functionality Confirming the Domestic call All alarm events need acknowledgement The transmission sequence is repeated until the control panel recieves an acknowledgement tome The control panel automatically hangs up after 45 seconds if it cannot detect the acknowledgement tone and redial later The user pr...

Страница 20: ...bert Bosch Engineering and Business Solutions Limited Glossary A Alarm Event that is configured as an alarm This is a particular situation motion detected doorbell rung signal lost etc that requires immediate attention An alarm can include live video playback video an action plan or a map ...

Страница 21: ...AMAX panel 2000 AMAX panel 2000 EN Notes en 21 Robert Bosch Engineering and Business Solutions Limited User Guide F 01U 249 500 V2 2011 11 Notes ...

Страница 22: ...22 en Notes AMAX panel 2000 AMAX panel 2000 EN F 01U 249 500 V2 2011 11 User Guide Robert Bosch Engineering and Business Solutions Limited ...

Страница 23: ......

Страница 24: ...Robert Bosch Engineering and Business Solutions Limited 123 Industrial Layout Hosur Road 560095 Bangalore India www bosch com Robert Bosch Engineering and Business Solutions Limited 2011 ...

Отзывы: