Access Modular
Controller 2
Introduction | en
13
Bosch Security Systems B.V.
2019-11 | V02 |
Status display
The liquid crystal display delivers status information about the
controller. Push the dialog button to switch between different
modes.
The selected display mode remains set until the next time the
button is pressed. The order of the display pages is shown in
the following table.
Push
Display (Example) Description
0
V01.00 02.03.07
or
LBUS or BG900
Software versions and date of the
firmware - every 5 sec. alternating
with the display of the reader
interface.
1a
S/N1: 0910019212 Bosch serial number
1b
S/N2: 00000001
2
02.06 15:35:15 (S) Current date and time
(S) = Summer; (W) = Winter
3
Dig. IO: :::::::::::::::: Display of the digital contacts: the
input signals set will be shown
with an extension above - output
signals with an extension below.
The first eight digits display the