![Bosch ACS 810 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/bosch/acs-810/acs-810_repair-instructions_50400022.webp)
| 22 | ACS 810 | Troubleshooting
en
1 689 975 253
2021-01-26
|
Robert Bosch GmbH
9. Troubleshooting
9.1
Service messages
Service message
Actions
CHANGE OIL
Change vacuum pump oil
(see section 12.7.1)
REPLACE FILTER
Replace combo filter
(see section 12.6.1)
9.2
Fault messages
failure indication
Actions
HIGH PRESSURE
There is excess pressure at the outlet of the compressor.
Turn off the ACS 810 and wait approx. 30 minutes.
PROGRAM ERROR
Error in the software.
FULL TANK
The internal refrigerant cylinder has been filled to maximum filling level.
Carry out several refill procedures to reduce the internal refrigerant quantity.
HIGH RECOVERY TIME
The recovery time exceeds the set maximum duration. Check the vehicle air
conditioning system for leaks. If error persists, contact customer service.
A/C SYSTEM EMPTY
There is no refrigerant in the vehicle air conditioning system.
A/C SYSTEM FULL
There is refrigerant in the air conditioning system.
INCOMPLETE CHARGE
The filling time exceeds the safe maximum duration set.
Pressure in internal refrigerant cylinder corresponds to pressure in vehicle
air conditioning system.
Содержание ACS 810
Страница 1: ...ACS 810 A C service unit en Repair instructions A C service unit ...
Страница 39: ......