2. 

User information

2.1 

User group

The product may be used by skilled and instructed 
personnel only. Personnel scheduled to be trained, fa-
miliarized, instructed or to take part in a general train-
ing course may only work with the product under the 
supervision of an experienced person.
All work conducted on pressurized equipment may be 
performed by persons with sufficient knowledge and 
experience in using pressurized devices and, also be 
aware of the risks involved in the use of pressurized 
devices.

2.2 

Agreement

Your use of the product means that you accept the fol-
lowing conditions:

Copyright

Software and data are the property of Bosch Limited, 
hereafter denoted as Bosch, or its suppliers and are 
protected against unauthorized reproduction under 
copyright laws, international contracts and other na-
tional legal provisions. Copying and selling of data 
and software or any other part thereof is prohibited 
and punishable by law. In the event of violations, 
Bosch Limited reserves the right to proceed with crimi-
nal prosecution and to claim for damages.

Liability

All data in this program is based - where possible - on 
manufacturer and importer details. Bosch does not ac-
cept liability for the correctness and completeness of 
software and data; liability for damage caused by faulty 
software and data is ruled out. Whatever the event, 
Bosch liability is restricted to the amount for which the 
customer actually pays for this product. This disclaimer 
of liability does not apply to damages caused by intent 
or gross negligence on the part of Bosch.

Warranty

Any use of non-approved hardware and software will 
result in a modification to our product and thus to 
exclusion of any liability and warranty, even if the hard-
ware or software has in the meantime been removed or 
deleted. No changes may be made to our products. Our 
products may only be used in combination with original 
accessories and original service parts. Failing to do so, 
will render null and void all warranty claims.

2.3 

Obligation of contractor

The contractor is obliged to ensure that all measures 
geared towards the prevention of accidents, industrial 
diseases, labor-related health risks are taken and mea-
sures towards making the workplace fit for people to 
work in are carried out.
The contractor is bound to ensure that all electrical 
equipment and operating material is set up, modified 
and maintained by skilled electricians only or under the 
guidance and supervision of a skilled electrician in ac-
cordance with electrical engineering principles.
Furthermore, the contractor must ensure that all elec-
trical equipment and operating material is operated in
keeping with electrical engineering principles.
If a piece of electrical equipment or operating material 
is found to be defective, i.e. it does not or no longer 
complies with electrical engineering principles, the con-
tractor must ensure that the fault is rectified immedi-
ately and, in the event that imminent danger exists, also 
ensure that the electrical equipment or the electrical 
operating material is not used.

2.4 

Safety Instructions

All safety instructions are to be read thoroughly before 
using the Bosch product and they must be observed.

 

R

Avoid the refrigerant coming into contact with the 
skin. The low boiling point of the refrigerant (approx-
imately -30 °C at atmospheric pressure) can cause 
frostbite. In case of contact with the skin, remove 
wet clothing immediately and rinse the affected area 
of skin with plenty of water.

Do not breathe in refrigerant or oil vapors. 
The vapors can irritate the eyes and the 
breathing passage of the nose. If liquid 
refrigerant/oil gets into the eyes, rinse the 
eyes thoroughly with water for 15 minutes. 
Then, seek medical attention, even if the 
eyes do not hurt.

 

R

Before the ACS 251 is connected to the vehicle A/C 
system or to an external refrigerant tank, ensure that 
the quick couplers do not leak. Use only external 
refrigerant tanks that are fitted with safety valves 
and approved in accordance with the applicable 
standards.

 

R

Before turning off the ACS 251, ensure that all the 
service phases are complete. This prevents refriger-
ant from escaping into the environment.

Содержание ACS 251

Страница 1: ...ACS 251 en Original instructions A C service unit ...

Страница 2: ......

Страница 3: ... 14 6 3 2 Editing vehicle details in the custom database 14 6 3 3 Deleting vehicle details from the custom database 14 6 3 4 Viewing custom database information 14 6 3 5 Transferring the custom database from one ACS 251 to another 14 6 4 Accessing the custom database 15 6 5 Automatic mode 15 6 5 1 Overview of automatic mode 15 6 5 2 Selecting the vehicle from the custom database 15 6 5 3 Setting c...

Страница 4: ...ot observed DANGER Immediate impending danger Death or severe injury WARNING Possible impending danger Death or severe injury CAUTION Possible dangerous situation Minor injury 1 1 2 Symbols in this documentation Symbol Designation Explanation Attention Warns about possible property dam age i Information Practical hints and other useful in formation 1 2 Multi step operation Instruction consisting o...

Страница 5: ... render null and void all warranty claims 2 3 Obligation of contractor The contractor is obliged to ensure that all measures geared towards the prevention of accidents industrial diseases labor related health risks are taken and mea sures towards making the workplace fit for people to work in are carried out The contractor is bound to ensure that all electrical equipment and operating material is ...

Страница 6: ...The ACS 251 must always be transported in a verti cal position Do not invert the ACS 251 R R There are no additional safety provisions for protect ing the ACS 251 unit against damage in the event of natural calamities like earthquakes fires floods etc R R Except for maintenance work do not remove any pressurized equipment inside the ACS 251 unit Adhere to the national laws or regula tions for ensu...

Страница 7: ...car A C systems that use R134a 3 2 Delivery specification Description ACS 251 Hose HP Hose LP Quick coupler HP Quick coupler LP Can assembly Used oil Can assembly Fresh oil Operating instructions Adapter for filling internal refrigerant tank 3 3 Description of unit 459897_ 110Nkv 1 2 3 4 5 6 7 8 9 11 14 12 13 10 15 Fig 1 Front view 1 Handle x 2 2 HP gauge 3 Status and warning light 4 LP gauge 5 LC...

Страница 8: ...ervice parameters can be done via the keypad The alphanumeric input keys can be used to enter letters and special characters in input fields In an input field pressing a key several times in succession displays all the characters it can be used for upper case letters special characters i i The alphabetical entries can be made in upper case only Keys Description AUTO Navigate to automode service me...

Страница 9: ...ack the knurled portion gently to re lease the coupler To attach the coupler to the service connection on the on the car A C system place the coupler on the service connection and pull back the knurled portion of the coupler Press gently 3 3 5 Brakes The ACS 251 can be prevented from rolling away by ap plying brakes Fig 2 Pos 6 on the rear wheels 3 3 6 Power cable and master switch The power cable...

Страница 10: ...el 3 Red and blue knobs 5 Open the rear panel Fig 5 Pos 2 6 Ensure that the red and blue knobs on the refriger ant tank are open 7 Close the rear panel 4 2 Before turning on for the first time 1 Remove the hoses HP and LP couplers from the packaging box 2 Apply the brakes on the rear wheels 3 Open the front panel 4 Open the screw cap of the vacuum pump Fig 6 Pos 1 1 2 45989 7_115 Nkv 3 4 Fig 6 Fil...

Страница 11: ... a flat vibration free surface 2 Apply the brake to prevent the unit from rolling away 3 Connect the power cable to the power inlet of the ACS 251 4 Connect the power cable to the mains supply i i Refer chapter 9 for the specifications of power supply 5 Turn on the master switch The self test is initiated The software version business logic version and the serial number of the ACS 251 are displaye...

Страница 12: ...isplayed on the HP manometer 7 Connect the power cable to the mains supply 8 Turn on the master switch 9 Press the MENU key on the keypad 10 Select Add Services Tank Fill 11 Follow the instructions on the screen i i To ensure reliable operation it is recommended to use the optimum refrigerant quantity The optimum refrigerant quantity for the ACS 251 is 4 kg 7 kg If the quantity is too less you may...

Страница 13: ...act customer service if the problem persists 7302 PS Sensor failure R R Contact customer service R R For error messages 7501 7502 7503 8000 and C001 contact customer ser vice 9102 FACTORY SETTING Not Complete R R Self test failed See the self test report and take corrective action A101 TANK FILL Service Timeout Check for blockage in the ACS 251 A103 TANK FILL Internal Tank full R R Weight limit re...

Страница 14: ...ch a maximum of 50 vehicles can be added The ve hicle model and R134a quantity for the vehicles can be entered at the workshop i i Refer to the vehicle documentation for the service parameters and other vehicle details To configure the custom database In the main menu select ACS Settings Custom DB 6 3 1 Adding new vehicle details to the vehicle database 1 Select New 2 Enter the following details M...

Страница 15: ... LP quick couplers in the counterclock wise direction disconnect from the service connec tions on the vehicle A C system 7 Press 8 Press to start draining refrigerant from the hoses Once the refrigerant is drained a summary screen is displayed The servicing of the vehicle A C system is complete 6 5 3 Setting custom parameters i i Once set custom parameters are valid only for a single service i i B...

Страница 16: ...he quantity drawn during the recov ery phase When filling a vehicle A C system for the first time refer to the vehicle documentation or the vehicle specific repair manual for the specified oil recharge quantity i i Use oil grade specified by the vehicle manufacturer Use only new oil to replace the oil removed during the recovery process Used oil should be discarded as per local regulations 6 6 5 R...

Страница 17: ...he refrigerant in the vehicle 6 8 2 Hose drain After every recharge top up some quantity of refriger ant is left in the hoses It is necessary to drain the re frigerant from the hoses 1 In the main menu select A C Services and press E Alternatively press the MENU button on the keypad 2 Select Add Services and press E 3 Select Hose Drain and press E The Hose Drain menu is displayed 4 Turn the HP LP ...

Страница 18: ... press E i i See chapter 5 for the description of the error messages 7 4 Vacuum pump oil change The vacuum pump oil needs to be changed after every 60 hours of operation When it is time to change the vacuum pump oil the message Replace Vacuum Pump Oil is displayed 1 Perform hose drain refer chapter 6 8 2 2 Disconnect the HP and LP hoses from the respective connectors 3 Turn off the master switch 4...

Страница 19: ...to the bracket of the ACS 251 i i Use a suitable spanner to unfasten or fasten the nuts 8 Hold the filter drier firmly and loosen the fastening nuts Fig 9 Pos 1 5 9 Detach the filter drier Fig 9 Pos 2 10 Connect the new filter drier Ensure that the O rings are present at the mating part of the filter 11 Tighten the fastening nuts Ensure that you tighten the fastening nut only after ensuring that t...

Страница 20: ...pter for the manifold while tightening the adapter for hoses Use tightening torque 9 5 N m 9 Connect the HP and LP hoses to the inline filters You have successfully replaced the inline filters 7 7 Self test When the ACS 251 is powered on a self test is initiated automatically It is also possible to trigger the self test manually In the main menu select ACS Maintenance Self Test Press E The self te...

Страница 21: ...efrigerants lubricants and oils Please dispose of the LCD display in accordance with the local regulations for disposal of special waste Refrigerants that can no longer be used must be hand ed over to the gas suppliers for disposal The lubricants and oils recovered from the A C systems must be handed back to the designated return points 8 3 Disposal of filter drier Dispose the filter drier through...