28
| English
Problem
Possible Cause
Corrective Measure
The LED on the dock-
ing station flashes
The perimeter wire is cutt, too long or too
short. Wire not connected and mower not
in the docking station.
Check that the perimeter wire is not interrupted and is
between 20 and 250 meters in length. Then switch
power supply off and then on again.
Follow instructions in Installation Guide to install the
mower.
Excessive vibrations/
noise
Blade bolt loose
Tighten blade bolt to torque of 2.5 Nm.
Cutting blade damaged/bent
Replace cutting blade (see figure
J
).
Mower not docking
reliably
Perimeter wire not properly layed out
around docking station
Follow instructions in Installation Guide on layout of peri-
meter wire.
Perimeter wire close to a source of interfer-
ence
Remove any excess (e.g. coiled up) perimeter wire
around the docking station.
Change perimeter wire ID in the menu.
Mower fails to operate Isolator switch not turned on
Remove mower out of docking station, turn isolator
switch on and place mower back into docking station (en-
sure docking station is on – LED lights up green).
Possible clogging
Always turn isolator switch off first, then check under-
neath the mower. Clear out as necessary (always wear
protective gloves).
Battery not fully charged
Place mower in the docking station to allow to charge.
Docking station must be on.
Grass too long
Mow lawn with conventional lawnmower to its lowest
height-of-cut setting before using the mower.
Battery too hot/cold
The mower operates when the battery internal battery
temperature is between 5 °C – 45 °C. Allow mower to
cool down/warm up. If the error occurs frequently, the
docking station should be positioned in the shade.
Mower standing on
lawn with the display
switched off
Operational problems
Press confirm button for screen to light up, or place
mower in docking station.
Mower does not
charge
Battery too hot/cold
The mower operates when the battery internal temperat-
ure is between 5 °C – 45 °C. Allow mower to cool down/
warm up. If the error occurs frequently, the docking sta-
tion should be positioned in the shade.
Docking station not switched on
Switch on power supply to docking station. If docking
station does not start, contact your Bosch Service
Centre.
Charging pins corroded
Clean the charging pins.
Mower out of peri-
meter wire
Perimeter wire on a slope
Leave 30 cm between the perimeter wire and the slope.
Obstacle near perimeter wire
Remove obstacle.
Parts of the lawn area
left uncut
Mower requires more cuts to finish garden Allow mower to run for 3 full cuts to cover whole lawn
area.
Time slot not long enough for garden size
Increase mowing time slot or use
"Bosch AUTO"
calen-
dar function.
Distance between perimeter wires too
small
Increase distance between the perimeter wires to a min-
imum of 75 cm.
F 016 L94 037 | (11.11.2020)
Bosch Power Tools
Содержание 3600HB0004
Страница 303: ... 303 2 m 5 m Indego XS 300 100 m 140 x C B Bosch Power Tools F 016 L94 037 11 11 2020 ...
Страница 304: ...304 1cm 3 0 c m 3 cm 3 cm 3 cm 3 cm E D F 016 L94 037 11 11 2020 Bosch Power Tools ...
Страница 305: ... 305 MAX 50 mm 40 mm MIN 30 mm MAX 50 mm MIN 30 mm STOP G F Bosch Power Tools F 016 L94 037 11 11 2020 ...
Страница 306: ...306 H F 016 L94 037 11 11 2020 Bosch Power Tools ...
Страница 307: ... 307 J I STOP STOP Bosch Power Tools F 016 L94 037 11 11 2020 ...
Страница 309: ... 309 10 min Software update Software update K Bosch Power Tools F 016 L94 037 11 11 2020 ...
Страница 310: ...310 F 016 L94 037 11 11 2020 Bosch Power Tools ...