LTC 2600 Series
| Instruction Manual
|
Multiplexer Read (MR) Commands
Bosch Security Systems | July 12, 2004
EN
| 32
MR-MON-TEXT
This command returns the foreground and background
brightness (respectively) for all text on all monitors.
Returned parameter values for <brightness> are:
0
Transparent
1
Black
2-6
Grey*
7
White
*NOTE: All grey values (2-6) will be returned as 2.
MR-MON-TEXT-ENABLE
<monitor>
This command returns the setting for text display on
the specified monitor.
Parameter values are:
<monitor>
1
Monitor A
2
Monitor B
<boolean>
0
Disabled
(returned value) 1
Enabled
MR-MON-TIME-DATE-FORMAT
This command returns the formats for the time and
date displayed on the monitor.
Returned parameter values are:
<time-format>
12
12 hr. mode
24
24 hr. mode
<date-format>
1
MM DD YY
2
DD MM YY
3
YY MM DD
MR-MON-TIME-ENABLE
<monitor>
This command returns the setting (enabled/disabled)
for the time/date display for the specified monitor.
Parameter values are:
<monitor>
1
Monitor A
2
Monitor B
<boolean>
0
Disabled
(returned value) 1
Enables
MR-MON-TIME-POSITION
This command returns the time/date display row
position for any enabled monitors and for both small
and large text. The row value corresponds to bottom,
middle, or top of the screen.
Returned parameter values for <location> are:
0 Time/date
display
OFF
1 Time/date
display
ON
2-31
(NTSC) Display row position
5-33
(PAL) Display row position
MR-OPERATION
This command returns the current system operation
mode.
Returned parameter values for <operation> are:
1
live
2
record
3
playback
4
playback-record (duplex and
duplex/System4 only)
5
record-record (duplex/System4 only)
6
playback-playback (duplex/System4
only)
MR-OPERATION-SIMPLEX
This command returns the operating mode for simplex
multiplexer models.
Returned parameter values for <mode> are:
1
Monitor A - live digital, record OFF
2
Monitor A - decoding, record OFF
3
Monitor A - live analog, record ON