42
| English
Measuring Tool Power Supply
The measuring tool can be operated either with conventional non-rechargeable batteries
or with a Bosch lithium-ion battery.
Operation with lithium-ion rechargeable battery pack (see figure A)
u
Use only the chargers listed in the technical data.
Only these chargers are matched
to the lithium-ion battery of your measuring tool.
Note:
The use of batteries unsuitable for your measuring tool can lead to malfunctions or
damage to the measuring tool.
Note:
The battery is supplied partially charged. To ensure full battery capacity, fully
charge the battery in the charger before using your tool for the first time.
The lithium-ion battery can be charged at any time without reducing its service life. Inter-
rupting the charging process does not damage the battery.
The lithium-ion battery is protected against deep discharge by the "Electronic Cell Pro-
tection (ECP)". A protective circuit switches the measuring tool off when the battery is
drained.
To
insert
the charged battery pack
(10)
, slide it into the battery bay
(25)
until you feel it
engage.
To
remove
the battery pack
(10)
, press the release buttons
(9)
and pull the battery pack
out of the battery bay
(25)
.
Do not use force to do this.
Operation with non-rechargeable batteries (see figure B)
It is recommended that you use alkaline manganese batteries to operate the measuring
tool.
The batteries are inserted into the battery adapter.
u
The battery adapter is intended only for use in designated Bosch measuring
tools and must not be used with power tools.
To
insert
the batteries, slide the receptacle
(28)
of the battery adapter into the battery
bay
(25)
. Place the batteries in the receptacle as shown in the picture on the cap
(27)
.
Slide the cap over the receptacle until you feel it click into place.
To
remove
the batteries
(26)
, press the release buttons
(9)
of the
cap
(27)
and pull off the cap. Make sure that the batteries do not fall
out by holding the measuring tool with the battery bay
(25)
facing up-
wards. Remove the batteries. To remove the receptacle
(28)
from in-
side the battery bay, reach into the receptacle and pull it out of the measuring tool, ap-
plying light pressure to the side wall as you do so.
Always replace all the batteries at the same time. Only use batteries from the same man-
ufacturer and which have the same capacity.
1 609 92A 5L5 | (11.01.2021)
Bosch Power Tools
Содержание 200 C
Страница 3: ...3 1 2 2 3 4 5 9 10 11 6 7 8 12 13 14 15 16 17 18 1 609 92A 5L5 11 01 2021 Bosch Power Tools ...
Страница 4: ...4 1 5 20 19 5 23 24 21 22 1 609 92A 5L5 11 01 2021 Bosch Power Tools ...
Страница 5: ...5 1 1 2 4 3 A B 25 9 10 25 26 9 27 28 1 609 92A 5L5 11 01 2021 Bosch Power Tools ...
Страница 6: ...6 A A B B C x x y y 1 609 92A 5L5 11 01 2021 Bosch Power Tools ...
Страница 7: ... 7 C R 2 0 3 2 3 V C R 2 0 3 2 3 V D 30 29 31 32 29 Bosch Power Tools 1 609 92A 5L5 11 01 2021 ...
Страница 382: ...382 فارسی 1 609 92A 5L5 11 01 2021 Bosch Power Tools ...