Bosch 1400 Series Скачать руководство пользователя страница 19

1200 Series IP Video Storage System

 Appendix | en

19

Bosch Sicherheitssysteme GmbH

Installation Manual

DOC | V1 | 2010.08

Note:

 This is a general block diagram and may not exactly represent the features on your 

motherboard. See the Motherboard Features pages for the actual specifications of each 

motherboard.

A.2

Chipset Overview

The X8SIL/X8SIL-F/X8SIL-V supports the Intel Xeon 3400 processor series. Built upon the 

functionality and the capability of the single-chip Intel 3400 chipset, the X8SIL/X8SIL-F/X8SIL-

V motherboard provides the performance and feature set required for single-processor-based 

systems with configuration options optimized for entry-level server platforms.The high-speed 

Direct Media Interface (DMI) featured in the Intel 3400/3420  chipset enables the X8SIL/

X8SIL-F/X8SIL-V motherboard to offer a high-speed Direct Media Interface (DMI) for chip-to-

chip true isochronous communication with the processor. This feature allows the X8SIL/

X8SIL-F/X8SIL-V to achieve up to 10 Gb/s of software-transparent data transfer on each 

direction, achieving better performance than comparable systems. The X8SIL/X8SIL-F/X8SIL-V 

also features a TCO timer (to enable the system to recover from a software/hardware lock), 

ECC Error Reporting, Function Disable and Intruder Detect.

Intel 3400/3420 Chipset Features

Direct Media Interface (up 10 Gb/s transfer, Full Duplex)

Intel Matrix Storage Technology and Intel Rapid Storage Technology

Dual NAND Interface

Intel I/O Virtualization (VT-d) Support

Intel Trusted Execution Technology Support

PCI Express 2.0 Interface (up to 5.0 GT/s)

SATA Controller (up to 3G/s)

Advanced Host Controller Interface (AHCI)

A.3

PC Health Monitoring

This section describes the PC health monitoring features of the X8SIL/X8SIL-F/X8SIL-V. These 

features are supported by an onboard System Hardware Monitor chip.

Recovery from AC Power Loss

BIOS provides a setting for you to determine how the system will respond when AC power is 

lost and then restored to the system. You can choose for the system to remain powered off (in 

which case you must hit the power switch to turn it back on) or for it to automatically return 

to a power on state. See the Power Lost Control setting in the BIOS chapter of this manual to 

change this setting. The default setting is Last State.

Onboard Voltage Monitoring 

The onboard voltage monitor will scan the following voltages continuously: CPU core, +3.3V, 

+5V, +/-12V, +3.3V Stdby, +5V Stdby, VBAT, HT, Memory, Chipset. Once a voltage becomes 

unstable, it will give a warning or send an error message to the screen.  Users can adjust the 

voltage thresholds to define the sensitivity of the voltage monitor by using SD III.

Fan Status Monitor with Software

PC health monitoring can check the RPM status of the cooling fans via Supero Doctor III.

CPU Overheat LED and Control 

This feature is available when the  user enables the CPU overheat warning feature in the BIOS. 

This allows the user to define an overheat temperature. When this temperature reaches this 

Содержание 1400 Series

Страница 1: ...1200 Series IP Video Storage System en Installation Manual ...

Страница 2: ......

Страница 3: ...erface 7 3 1 Control Panel Buttons 7 3 2 Control Panel LEDs 7 4 Installation 9 5 Chassis Setup and Maintenance 10 5 1 Removing the Chassis Cover 10 5 2 Rotating the Hard Drive Cage 11 5 3 Removing and Installing Hard Drives 11 5 4 Installing the I O Shield and Motherboard 13 5 5 Installing the System Fan 13 5 6 Power Supply 13 A Appendix 14 A 1 Motherboard layout 14 A 2 Chipset Overview 19 A 3 PC ...

Страница 4: ...tlet If an electrical accident occurs you can then quickly remove power from the system Do not work alone when working with high voltage components Power should always be disconnected from the system when removing or installing main system components such as the serverboard memory modules and optical device drives When disconnecting the power you should first power down the system with the operati...

Страница 5: ... 1 6 System Safety Electrostatic discharge ESD is generated by two objects with different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipme...

Страница 6: ... or screws The chassis is equipped with high efficiency power supply High performance fans provide ample optimized cooling for FB DIMM memory modules and four hot swap drive bays offer maximum storage capacity For information on supported hardware see the datasheet for the 1200 Series in the Bosch Online Product Catalog For more detailed technical information on your device refer to http www super...

Страница 7: ...you may need to take 3 1 Control Panel Buttons Power The main power button is used to apply or remove power from the power supply to the system When the power is on the power button will be lighted by a blue LED Turning off the system power with this button will cause the blue LED to turn off and will remove the main power but will keep standby power supplied to the system Therefore you must unplu...

Страница 8: ...When Continuously On not flashing This LED indicates an overheat condition caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Correcting an Overheat Fan Fail Condition 1 Check the routing of the cables and move any cables the restrict airflow 2 Confirm that all fans are operating normally 3 Verify that the heatsinks are installed properly 4 If the...

Страница 9: ... en 9 Bosch Sicherheitssysteme GmbH Installation Manual DOC V1 2010 08 4 Installation The systems comes pre installed and only hard drives may be exchanged onsite In case of any other failure the entire system has to be exchanged by advanced exhange ...

Страница 10: ...ngs and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter System Safety and the warning precautions listed in the setup instructions 5 1 Removing the Chassis Cover Removing the Chassis Cover 1 Push the power button to turn off the power to the system 2 Disconnect the chassis from any power source 3 Slide the release tab A towards the ...

Страница 11: ...onnect the chassis from any power source 2 Lift the release tab A 3 Rotate the hard disk drive cage B outward 5 3 Removing and Installing Hard Drives The 1200 Series chassis must be powered down before hard drives can be removed from the hard drive carriers Removing and Installing Hard Drives 1 Disconnect the chassis from any power source 2 Rotate the hard drive cage outward 90 degrees as describe...

Страница 12: ... hard drive cage 6 If a hard drive is already present remove it by carefully pulling the sides of the hard drive carrier outward 7 Remove the hard drive from the hard drive carrier 8 Insert the new hard drive into the hard drive carrier 9 Insert the hard drive carrier into the hard drive cage sliding it towards the back of the the hard drive cage until it clicks into a locked position ...

Страница 13: ... I O Shield and Motherboard Motherboard problems will be handled by trained support people only 5 5 Installing the System Fan System fan problems will be handled by trained support people only If the system fan has to be replaced the entire unit will be exchanged advanced exchange service Note The fan noise of the system is a factor to note When it occurs this can be an indication of impending fai...

Страница 14: ...IO1 T SGPIO2 J24 JLAN2 JLAN1 SPKR1 JBT1 1 JI2C1 1 JI2C2 1 LE4 LE2 LE3 LE7 JPT1 1 JPB JLED1 1 1 JPUSB1 1 JPL1 1 JPL2 JPG1 JD1 1 FAN2 FAN1 FAN5 1 FAN4 FAN3 J16 PCI1 U2 BAR CODE 1 2 ENABLE 2 3 DISABLE JPL2 LAN2 JPL1 LAN1 2 3 DISABLE 1 2 ENABLE JPB BMC JPI2C PWR I2C JD1 Buzzer Speaker COM2 FLOPPY DDR3 1066 1333 UDIMM RDIMM required VGA COM1 USB4 JBT1 CMOS CLEAR SLOT7 PCI E X8 GEN2 JPT1 TPM JL1 LAN1 JP...

Страница 15: ... JBT1 CMOS Clear 40 JPES Energy Saving Feature Pins 2 3 Disabled 13 14 JI2C1 JI2C2 SMB to PCI Slots 17 JPG1 Onboard VGA Enable Pins 1 2 Enabled 11 12 JPL1 JPL2 LAN1 LAN2 Enable Pins 1 2 Enabled 24 JPT1 TPM Enable Pins 1 2 Enabled 10 JPB BMC Jumper Pins 1 2 Enabled X8SIL X8SIL F X8SIL V Headers Connectors Number Connector Description 4 16 COM1 COM2 COM1 2 Serial connection headers 33 32 27 23 7 Fan...

Страница 16: ... USB0 1 USB 2 3 Backplane USB 0 1 Front panel accessible USB 2 3 19 USB 4 Type A USB Connector 18 USB 10 11 Front Panel USB header X8SIL F Only 22 DOM PWR Disk On Module DOM Power Connector 39 JTPM Trusted Platform Module TPM Header 6 VGA Onboard Video Port X8SIL X8SIL F X8SIL V LED Indicators Number LED Description Color State Status 26 LE4 Onboard Standby PWR LED Green Solid on PWR On 15 LE7 IPM...

Страница 17: ...he rear IO panel Two 2 USB header connectors for front access One 1 Type A internal connector I O Devices Continued USB Devices X8SIL F X8SIL V Only Two 2 USB ports on the rear IO panel Four 4 USB header connectors for front access One 1 Type A internal connector Keyboard Mouse PS 2 Keyboard Mouse ports on the I O backplane Serial COM Ports Two 2 Fast UART 16550 Connections one 9 pin RS 232 port a...

Страница 18: ...lities BIOS flash upgrade utility Drivers and software for Intel 3400 3420 chipset utilities Other ROHS 6 6 Full Compliance Lead Free Dimensions Micro ATX form factor 9 6 x 9 6 Clarkdale IBexPeak BLOCK DIAGRAM DDR3 CHA Lynnfield PCIe2 0_x8 VRM 11 1 VID 0 7 RoHS 6 6 LPC I O W83627DHG PCIe x8 SLOT RJ45 RJ45 DDR3 CHB DIMM1 Far DIMM2 DIMM1 Far DIMM2 4 UDIMM MISC VRs 1333 1066MHz 1333 1066MHz 5 0Gb x4 ...

Страница 19: ...hnology and Intel Rapid Storage Technology Dual NAND Interface Intel I O Virtualization VT d Support Intel Trusted Execution Technology Support PCI Express 2 0 Interface up to 5 0 GT s SATA Controller up to 3G s Advanced Host Controller Interface AHCI A 3 PC Health Monitoring This section describes the PC health monitoring features of the X8SIL X8SIL F X8SIL V These features are supported by an on...

Страница 20: ...ard A 5 Power Supply As with all computer products a stable power source is necessary for proper and reliable operation It is even more important for processors that have high CPU clock rates of 1 GHz and faster The X8SIL X8SIL F X8SIL V accommodates ATX12V standard power supplies Although most power supplies generally meet the specifications required by the CPU some are inadequate A 2 Amp of curr...

Страница 21: ...host servers Unlike fiber optic networks that require special cabling iSCSI can run over long distance using existing networks For the X8SIL X8SIL F X8SIL V motherboard iSCSI is supported on LAN 1 This can be enabled through the BIOS Advanced PCI PnP Configuration Onboard LAN1 Option ROM Select A 8 Overview of the Nuvoton BMC Controller The Nuvoton WPCM150 is a combined Baseboard Management Contro...

Страница 22: ...22 en Appendix 1200 Series IP Video Storage System DOC V1 2010 08 Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 23: ......

Страница 24: ...Bosch Sicherheitssysteme GmbH Werner von Siemens Ring 10 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2010 ...

Отзывы: