0 986 629 001 | 2018-02-28
Robert Bosch GmbH
458919-05_shd
8:
Disconnecting the hose assembly
7. Place the hose assembly with the hose open-
ing facing downward
in the container
for the fuel.
Allow the fuel to drain into the container.
1
2
458919-06_shd
9:
Emptying fuel into the container
(1) Hose assembly
(2) Container
8. Once the graduated measuring cylinder is com-
pletely empty, push the hose assembly into the
plug connector as far as possible.
9. Place the plug connector in the opening of the
graduated measuring cylinder connector cap
(2)
.
458919-07_shd
1
2
10:
Plug connector in the graduated measuring cylinder
connector cap
(1) Plug connector
(2) Graduated measuring cylinder connector cap
10.Dispose of remaining fuel in accordance with
the regulations of the respective country.
In Germany, the Technical Rules for Hazard-
ous Substances (TRGS) apply to handling
and disposal of the remaining fuel. Failure
to comply with the TRGS poses the risk of
environmental pollution.
4. Maintenance
4.1 Ultrasonic cleaning
Use only a soft cloth and neutral cleaning
agents to clean the housing.
Coarse workshop rags and abrasive clean-
ing agents may damage the 0 986 612 950 .
4.2 Spare parts
Denomination
Part number
Hose, 2 m
<)
0 986 612 905
O-ring parts set (10 pcs), 3.5 x 1.2
<)
0 986 613 289
Adapter module (plug connection with
ball valve)
<)
0 986 613 329
<) Wearing part
4.3 Replacing the hose assembly
1
2
3
4
5
458919-01_shd
11:
Replacing the hose assembly
(1) Hose assembly
(2) Plug connector
(3) Quick-release coupling on the plug connector
(4) Screw connection
(5) Quick-release coupling on the screw connection
1. Press the quick-release coupling on the plug
connector
upward.
2. Pull the hose assembly
458919-01_shd.svg
(1)
downward.
3. Press the quick-release coupling on the screw
connection
458919-01_shd.svg
(4)
upward.
4. Pull the hose assembly
458919-01_shd.svg
(1)
downward.
5. Cut 40 cm off the new hose assembly
0 986 612 905.
en | 14 |
0 986 612 950
| Maintenance
Содержание 0 986 612 950