Bosch Rexroth AG VT 3000 Скачать руководство пользователя страница 5

Hydraulics

    Bosch Rexroth AG

RE 29935/10.12    VT 3000

5

/8

Technical data 

(For application outside these parameters please consult us!)

Operating voltage 

1)

U

B

24 VDC +60 % –5 %

Operating range: 
– Upper limit value

u

B

(t)

max

39 V

– Lower limit value

u

B

(t)

min

22 V

Power consumption

P

S

< 50 VA

Current consumption

I

< 1 A (with loading current)

Fuse

I

S

2.5 A slow 

Inputs:
– Command values 1 to 4

U

e

±9 V (reference potential is M0)

– Command value 5

U

e

±6 V (reference potential is M0)

– Command value 6 (differential input)

U

e

0 to ±10 V; 

R

e

 = 100 kΩ

Ramp time (setting range)

t

30 ms to approx. 1 s or 5 s

Outputs:
– Output stage
  • Solenoid current/resistance

I

max

800 mA; 

R

(20)

 = 19.5 Ω

  • Biasing current

I

V

20 mA ±25 %

  • Pulse frequency

f 170 Hz ±10 %

– Regulated voltage

U

±9 V ±1 %; ±25 mA externally loadable

– Measuring sockets
    • Current command value „W“

U

±6 V; 

R

i

 = 5 kΩ

  • Current actual value „I

A

“; „I

B

U

A

U

B

0 to 800 mV equivalent 0 to 800 mA

Relay data:
– Nominal voltage

U

operating voltage 

U

B

– Threshold voltage

U

16.8 V

– Return voltage

U

2.4 V

– Coil resistance

R

2150 Ω

Type of connection

32-pin terminal strip, DIN 41612, form D

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front plate dimensions
– Height

3 HE (128.4 mm)

– Width soldering side

1 TE (5.08 mm)

– Width component side

7 TE

Permissible operating temperature range

0 to 50 °C

Storage temperature range

–25 to 85 °C

Weight

m

0.13 kg

1)

 To guarantee the max. solenoid current for the solenoid 

(19.5 Ω) in the complete solenoid temperature range the 
operating voltage must be at least 28 VDC!

Note:

For details regarding 

environmental simulation test

 in the 

field of EMC (electromagnetic compatibility), climate and me-
chanical stress, see data sheet 30304-U (declaration on envi-
ronmental compatibility).

Содержание VT 3000

Страница 1: ...table with potentiometers Four command value call ups with LED display Differential input Step function generator Ramp generator Two pulsed current output stages Polarity protection for the voltage supply Note When supplied the amplifiers have a ramp time of 5 s setting of the ramp time of 1 s see page 6 Contents Page Features 1 Ordering code 2 Functional description 2 Block circuit diagram pin al...

Страница 2: ...lue is called up simultaneously the input with the highest num ber has priority Example If command value 1 and command value 3 are activated simultaneously the command value 3 becomes effective A further output of the card provides a supply voltage for the command value call ups which can be switched over from 9 V to 9 V with the relay K6 1 All relays on the card are switched with 24 VDC smoothed ...

Страница 3: ...d A voltage of 6 V at the command value test point W corresponds to a com mand value of 100 A positive command value signal at the input of the amplifier controls the output stage for solenoid B a negative com mand value signal the output stage for solenoid A If the command value signal is smaller than 1 step function still ineffective a pilot current of 20 mA flows through both sole noids The act...

Страница 4: ...d by 9 V compared to 0 V operating voltage Call up command value 1 Call up command value 2 Call up command value 3 Call up command value 4 Call up Ramp off Call up Switch over aux voltage Relay call up voltage 24 V Current command value at w 0 to 6 V for solenoid A 0 to 6 V for solenoid B Current actual value I A at I A Current actual value I B at I B Biasing current solenoid A Solenoid A Solenoid...

Страница 5: ... loadable Measuring sockets Current command value W U 6 V Ri 5 kΩ Current actual value IA IB UA UB 0 to 800 mV equivalent 0 to 800 mA Relay data Nominal voltage U operating voltage UB Threshold voltage U 16 8 V Return voltage U 2 4 V Coil resistance R 2150 Ω Type of connection 32 pin terminal strip DIN 41612 form D Card dimensions Euro card 100 x 160 mm DIN 41494 Front plate dimensions Height 3 HE...

Страница 6: ...command value 1 H2 Call up command value 2 H3 Call up command value 3 H4 Call up command value 4 H11 Operating voltage Power on yellow H12 Indication Ready for operation green Potentiometer w1 Command value 1 w2 Command value 2 w3 Command value 3 w4 Command value 4 t1 Ramp time Measuring sockets W Command value solenoid current IA Actual current value solenoid A IB Actual current value solenoid B ...

Страница 7: ... operating voltage When switching command values use relays with gold contacts small voltages small currents When switching card relays only use contacts with a loadability of approx 40 V 50 mA When controlling externally the control voltage may have a maximum residual ripple of 10 Always screen command value lines connect screen to 0 V operating voltage on the card side other side remains open da...

Страница 8: ...e reproduced or given to third parties without its consent The data specified above only serve to describe the product No statements concerning a certain condition or suitability for a certain application can be derived from our information The information given does not release the user from the obligation of own judgment and verification It must be remembered that our products are subject to a n...

Отзывы: