BorMann Technik MY2800 Скачать руководство пользователя страница 17

 
 

 

Fuses blow /circuit 

breaker trips 

repeatedly. 

CAUTION!

 

Never 

use an extension 

cord with this 

product

 

1.

 

Incorrect size fuse, 

circuit overloaded. 

2.

 

Defective check valve or 

unloaded 

1. Check for proper fuse, use time-delay fuse. 

Disconnect other electrical appliances from circuit 

or operate compressor on its own branch circuit 

2. Replace or repair. 

DANGER! 

Never disassemble check valve under 

pressure. release tank firstly 

Thermal overload 

protector cuts out 

repeatedly 

1.

 

Low voltage 

2.

 

Clogged air filter 

3.

 

Lack of proper 

ventilation/room 

temperature too high 

4.

 

Check valve malfunction 

5.

 

Compressor valves failed 

1.

 

Eliminate extension cord, check with 

voltmeter 

2.

 

Clean filter (see Maintenance section) 

3.

 

Move compressor to well ventilated area 

4.

 

Replace 

5.

 

Replace valve assembly 

DANGER! 

Never disassemble check valve under 

pressure. release tank firstly 

Knocks, rattles, 

excessive vibration 

1.

 

Loose bolts, tank not 

level 

2.

 

Defective bearing on 

eccentric or motor shaft 

3.

 

Cylinder or piston ring is 

scored 

1.

 

Tighten bolts, shim tank to level position 

2.

 

Replace 

3.

 

Replace or repair as necessary 

Tank pressure drops 

when compressor 

shuts off 

1.

 

Loose drain cock 

2.

 

Check valve leaking 

3.

 

Loose connections at 

pressure switch or 

regulator 

1.

 

Tighten   

2.

 

Disassemble check valve assembly, clean or 

replace 

3.

 

Check all connections with soap and water 

solution and tighten   

Compressor runs 

continuously and air 

output is lower than 

normal/low 

discharge pressure 

1.

 

Excessive air usage, 

compressor too small 

2.

 

Clogged intake filter 

3.

 

Air leaks in piping (on 

machine or in outside 

system) 

4.

 

Broken inlet valves 

5.

 

Piston ring worn 

1.

 

Decrease usage or purchase unit with higher 

air delivery (SCFM) 

2.

 

Clean or replace 

3.

 

Replace leaking components or tighten as 

necessary 

4.

 

Replace compressor valves 

5.

 

Replace piston and cylinder 

Excessive moisture 

in discharge air 

1.

 

Excessive water in tank 

2.

 

High humidity 

1.

 

Drain tank after every use.     

2.

 

Move to area of less humidity; drain air tank 

more often in humid weather and use air line 

filter. 

NOTE: Water condensation is not caused by 

compressor malfunction 

Compressor runs 

continuously 

and 

safety valve opens 

as pressure rises 

1.

 

Defective pressure 

switch 

2.

 

Defective safety valve 

1.

 

Replace switch 

2.

 

Replace safety valve with genuine 

replacement part 

Excessive starting 

and 

stopping  

(auto start) 

Excessive condensation in 

tank 

Drain more often 

Air  leaking from 

release valve on 

pressure switch 

Check valve stuck in an open 

position 

Remove and replace check valve 

DANGER! 

Never disassemble check valve under 

pressure. release tank firstly

 

 

 

 

Содержание Technik MY2800

Страница 1: ...My2800 Owner s manual www BormannTools com...

Страница 2: ...2 www BormannTools com GR DIY 8 Bar...

Страница 3: ...3 www BormannTools com 1 2 NEC OSHA 3 4 5 6 7 8 9 10 11 12...

Страница 4: ...4 www BormannTools com 13 14 15 16 17 18 1 2 110V 230V 50Hz 60Hz 750W 50L 7 Bar 1 2...

Страница 5: ...5 www BormannTools com 40 C 1 230 volt 5...

Страница 6: ...6 www BormannTools com 230 V 5 230volt 5 15 230V 5 AUTO 0 8Mpa 0 6Mpa OFF OFF 1 Bar 1 2 OFF 3 AUTO 30 4...

Страница 7: ...7 www BormannTools com 8 5 6 bar 6 OFF 7 AUTO OFF OFF 6 1 2 6...

Страница 8: ...8 www BormannTools com 1 2 2 1 2 3 SAE30 1 2 3...

Страница 9: ...9 www BormannTools com 1 2 3 1 2 3 4 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 1 2 1 2 3 4 1 2 3 4 5...

Страница 10: ...10 www BormannTools com 5 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 4 5 1 SCFM 2 3 4 5 1 2 1 2 1 2 1 2...

Страница 11: ...s important information that if not followed MAY cause damage to equipment Unpacking Before and after unpacking the package inspect carefully for any damage that may have occurred during transit Make...

Страница 12: ...modify a tank Welding drilling or any other modification will weaken the tank resulting in damage from rupture or explosion Always replace worn or damaged tanks WARNING Drain liquid from tank daily 13...

Страница 13: ...an extension power cord voids the warranty GROUNDING INSTRUCTIONS 1 This product is for use on a nominal 230 volt circuit and has a grounding plug that looks like the plug illustrated in Fig 5 Make su...

Страница 14: ...tically when tank pressure reaches the minimum preset pressure about 0 6Mpa In the OFF position the compressor will not operate This switch should be in the OFF position when connecting or disconnecti...

Страница 15: ...the spray material IMPORTANT This condensation will cause water spots in a paint job especially when spraying other than water based paints If sandblasting it will cause the sand to case and clog the...

Страница 16: ...nd compressor in a cool dry place 2 Exhaust water from tank 3 Disconnect hose and hang it on top of compressor to avoid TROUBLESHOOTING CHART Symptom Possible Cause s Corrective Action Compressor can...

Страница 17: ...oose connections at pressure switch or regulator 1 Tighten 2 Disassemble check valve assembly clean or replace 3 Check all connections with soap and water solution and tighten Compressor runs continuo...

Страница 18: ...8 EXPLODED VIEW FOR SILENT OILFREE AIR COMPRESSOR...

Страница 19: ...18 550W motor foot SET 4 19 OFS550 19 bearing for motor PC 2 20 OFS550 20 550W motor stator PC 1 21 OFS550 21 550W motor rotor PC 1 22 OFS550 22 bolt for motor PC 4 23 OFS550 23 crankcase cable side...

Отзывы: