Sanitisation Guide
NOTE:
All maintenance operations must be carried out with the dispenser switched off. This
operation must only be carried out by trained staff. Every 6 months a sanitisation procedure is
recommended as follows:
Turn off incoming mains water.
Connect to filter head.
Add 25 ml of Bioguard Internal
Sanitisation fluid to a clean and
empty service filter cartridge.
Turn on incoming water, allow
service cartridge/doser to fill.
1
3
2
4
5
7
Dispense water using the cold
button until the water appears pink.
Briefly press the ambient button
too. Repeat with sparkling button
if present.
Briefly press cold/ambient dispense
button to release internal water
pressure from the machine.
Remove the existing filter.
Use Bioguard Hand Gel and put
on protective gloves.
8
Leave the solution inside machine
for sanitisation to take effect
(minimum 5 minutes) while
thoroughly cleaning the machine
externally
9
6
PINK
5