Waste Electrical Products:
- The WEEE symbol indicates that this item contains electronic components which must be
collected and disposed of separately.
- Never dispose of electrical waste in general municipal waste. Collect and dispose of
such waste separately.
- Make use of the return and collection systems available to you, or your local recycling
programme. Contact your local authority or place of purchase to find out what schemes
are available.
- Electrical and electronic equipment contains hazardous substances which, when disposed
of incorrectly, may leak into the ground. This can contribute to soil and water pollution
which is hazardous to human health; and endangers wildlife.
- It is essential that consumers look to re-use or recycle electrical or electronic waste to avoid
it going to landfill sites or incineration without treatment.
Basic Troubleshooting
Problem/Report
Possible Cause
Suggested Action
No water dispensing
Water supply turned off
Check that power supply, and all taps/ valves/ filters
on the incoming water supply are fitted and are turned
on
Leak detection in unit triggered
Disconnect the power and water supply, check for
leaks.
Faulty water pressure regulator, or other failure
Contact your distributor
Hot tank dry start
Check on heater connections and water supply
Waste kit full
Empty level sensor tank
No/low sparkling water
No/incorrect CO2 pressure
Check CO2 bottle, regulator and non-return valve.
Replace as necessary
Carbonator tank not filling
Contact your distributor
Warm drinks
Insufficient cooling air flow through the fridge
Contact your distributor
Faulty compressor, or other failure
Water lying on top edge of
lower door panel and/or bottom of
cabinet.
Overflowing drip tray waste container
Empty waste container and check drainpipe is not
blocked
Water lying in bottom of machine
Leak in pipe work and/ or filter
Contact your distributor
Bleeping noise
Level sensor fitted and tank full
Empty level sensor tank
Not all symbols showing
Unit is in heater commissioning mode
Check water is dispensing then hold lock symbol
10secs
Refer to instruction manual for full fault codes and diagnostics.