1
2
3
4
To install the filter, proceed as follows:
1. Before installing, make the appropriate cut outs according to the type of installation. It is
necessary to leave an inspection hatch on the ceiling to access the filter without having to
remove the hood in the event of a service call.
2. Take the necessary measurements to calculate the installation path and the number of
additional conduits needed.
3. Mount the entire system outside the false ceiling for better ease.
4. Position the system in place and connect it to the power supply..
5. Mount the hood connecting the filtering system to the motor output and connect it.
GB
Page 20 of 36
White lacquered grid to fit the tube ducts.
Fixation by magnets.
RECOMMENDED ACCESSORY
Installation of the Plasma filter in ceiling hoods
Box content:
Plasma filter
Données techniques:
Power 210-250v ~ 50Hz, 10W
The Plasma filter can be easily installed on ceiling hoods by simply connecting it to the motor
outlet and channelling it to an exhaust grid, using flexible piping (non supplied).
This grid can be located at floor plan on the false ceiling (Fig. 1,2), or on the side of an enclosed
hanging false ceiling as shown in Fig. 3,4.
For optimum performance, it is advisable to install the filter as far as possible, without exceeding
3 m.
Installation examples
Содержание PURO QUADRO 800
Страница 30: ...Pagina 30 di 32 ...