36
Electrical connection
• The installation of this appliance and the connection to the electrical network should be entrus
-
ted only to an electrician perfectly to the fact of the normative regulations and which respects
them scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The data of connection necessary are on the stickers place on the hob casing near the con
-
nection box.
• The connection to the main must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be incorporated
in the fixed installation, in accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or oven.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz. Connect always the earth
wire. Respect the connection diagram. The connection box is located underneath at the back of
the hob casing. To open the cover use a medium screwdriver. Place it in the slits and open the
cover.
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has
been equipped with a faulty earth connection.
Mains
Connection
Cable diameter Cable
Protection
calibre
230V~ 50/60 Hz (BE)
1 Phase + N
3 x 2.5 mm²
H 05 VV – F
25 A*
H 05 RR – F
400V~ 50/60Hz (NL)
2 Phase + 2 N
5 x 2.5 mm²
H 05 VV – F
2 x 16 A*
H 05 RR – F
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal.
Monophase 230V~1P+N
Put the 1st bridge between terminal 1 and 2, the 2nd between 4 and 5.
Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 5, the Phase L to one of
the terminals 1 or 2.
Biphase 400V~2P+N
Put the 1st bridge between terminal 4 and 5.
Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 5, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution! Be careful that the cables are correctly engaged and tightened.
Содержание BIKP-78
Страница 1: ...NL FR BIKP 78 GEBRUIKSAANWIJZING NOTICE D EMPLOI Boretti B V BIKP 78 inductiekookplaat 11 ...
Страница 38: ......
Страница 39: ......
Страница 41: ...D EN BIKP 78 BEDIENUNGSANLEITUNG OPERATING INSTRUCTIONS Boretti B V BIKP 78 inductiekookplaat 11 ...
Страница 78: ......
Страница 79: ......