13
4.5.4 pattern control
On the Pattern Control page, users can configure the trigger out, trigger in and
pattern ready signals and to control the display of patterns in internal pattern mode.
This page requires the EVM to be connected to the GUI in order to work.
Configure the triggers and pattern ready signal as required and click Set. To view
the current configuration of these signals, click Get. After all the configurations are
set, the user can select and control how to run these patterns:
run once, run continuously, pause, step, stop, reset
In trigger in mode, module project only one pattern when receive one trigger
signal.
The configuration take effect after click “set” button, but will lost after
disconnect the power source. If user wish to storage the configuration, could make a
batch file, and program it into a firmware, and then write it in flash.