10
10
GPIB
24-pin GPIB (IEEE-488) connector for connecting the signal
generator to the remote control General Purpose Interface Bus.
GPIB parameters can be configured through the menu.
11
AC Line Input
A multi-function power input module is used to house the AC
line input, main power switch, and safety fuse. The module
accepts a standard AC line cord, included with the signal
generator. The power switch is used to shut off main instrument
power. The safety fuse may also be accessed once the line cord
is
removed. The instrument’s power supply accepts 90 to
264 VAC, so no line voltage selection switch is necessary.
Caution
Replace fuse only with specified type and rating:
1.0A-T (time delay type), 250 VAC.
12
LAN
LAN/Ethernet connector for remote control. Allows DHCP or
fixed (IP / Subnet) setting mode. LAN parameters can be
configured through the menu.
13
Ref In
10 or 100 MHz reference input.
14
Ref Out
100 MHz reference output.
15
Trig In
BNC input for connecting an external trigger signal to the signal
generator.
16
Multi I/O
BNC input/output reserved for future use.
Figure 3-2. SGX1018 RF Signal Generator - Rear Panel