Circleslide
>
#
#
<
><
<< >>
>> <<
<
>
EXIT
30 min.
max.
30 min.
max.
>30 min.
30 min.
max.
>30 min.
30 min.
max.
>30 min.
Safety- and operating instructions
A. The Circleslide safety devices
1 Reversing- and stop mechanism.
2 Threshold Safety (THS).
3 Side wing Safety (SWS).*
4 Emergency power system (day).
5 Emergency unlocking.
6 Emergency open button.*
7 Fire alarm.*
B. Last action after power failure.*
1 Sliding doors will open.*
2 Sliding doors will close, doorset locks.*
3 Sliding doors will close, doorset unlocked.*
C. Operating modes
1 Automatic mode.
2 Night mode (closed).
3 Permanently open mode.
4 Manual mode.
5 One-way mode (outer doorset).
6 Winter mode.
7 Key-impuls switch.*
8 Free out pushbutton.*
9 Interlocking.*
10 Reset mode.
Control panel
A. The Circleslide control panel
1 Control panel inside door.
Keys
C-key (Cancel)
Exit menu.
OK-key.
Confim the selection.
Arrow keys.
Navigate within
the menus.
Inner
doorset
Outer
doorset
Display
Section frame
Indicating priority operating mode
with key switch.
Section frame
Indicating operating mode selected
with control panel.
Automatic mode.
Night mode (closed).
Permanently open mode.
Manual mode.
One-way mode.
Winter mode, reduced opening width.
Summer mode, full opening width.
Closed and locked.*
Closed.
Opening.
Closing.
Open.
B. Control panel Inter-locking*
1 Control panel inside door.
1 Inter-locking mode enabled.
2 Inter-locking mode disabled.
3 Night mode, outer doorset locked.
C. Free out pushbutton*
1 Control panel inside door.
1 Free out (one passage, in night position).
D. Entry (one passage, in night position)*
1 Key switch outside door.
1 Entry (one passage, in night position).
E. Escape route*
1 Control panel inside door.
1 Escape route enabled, doorset unlocked.
2 Escape route disabled, doorset locked.
Version
: 2015/01/12
Edition
: CS-INS-UK