BooCax
6
/
13
www.boocax.com
Product manual of Plasma Air Sterilizer (BKS-LTP-DP01) V1.0.5
---
In a closed space of about
100m³
, set the disinfection program to work for 60mins, the killing
rate of natural bacteria in air is
≥
92.86%
,
and for the same environment, this killing rate is
≥
96.05%
when the program work set to 120mins.
---
The killing rate of influenza A (H1N1) is
99.99%
per 60mins,
30m³
of closed space.
--- The PM2.5 elimination rate reaches
99.98%
per 60mins,
30m³
of closed space.
---
The
Formaldehyde elimination rate reaches
97.6%
per 24 hours,
30m³
of closed space.
4.
Product Parameters
Type
Item
BooCax Plasma Air Sterilizer
Basic
parameters
Model No.:
BKS-LTP-DP01
Function:
to eliminate bacteria in the air, remove peculiar smell
and formaldehyde by plasma technology
Overall size:
900mm*530mm*330mm
Product weight:
26.5kg
Applicable environment
temperature
0℃
-
50℃
Performance
Parameters
Air volume
≤1000m³/h(
four levels for adjust
)
Applicable space
100
㎡
noise
≤70db,
the minimum level is 35dB
Plasma density
7.81 × 10
17
𝑚
−3
~2.27 × 10
18
𝑚
−3
Elimination rate
Simulated field≥99.9%,
on-
site natural field≥90%
Notice
Fan speed level
A
ir volume (m³/h)
Noise dB
1
260
35
2
375
45
3
750
55
4
1000
70
Mobility
Motion type
Silent universal wheel