4. INSTALLATION : CONNECTIONS
4.1 ELECTRICAL CONNECTION
C o n n ec t t he a pp l i an c e be fo r e i t i s fi n al l y l oc a te d .
- Follow the procedure to access items within the housing.
- Undo the two screws holding the access panel on the back of the unit.
- Pass the supply cable through the cable gland and out through the rear access panel.
- Tighten the cable gland
- Refit the rear access panel.
- Connect the wiring to the unit.
- Refit the cover and the compressor compartment door.
IMPORTANT:
Only electrical cable type HO 7 RNF with cross-section 3 x 1.5 mm
2
should be used.
Provide a suitable isolating device (with contact separation of at least 3mm) in accordance with
current regulations.
The installation comply with current applicable national legislation (for France, standard NF
15.100)
The appliance must be connected to the earth. The various electrical appliances must also be
connected with an equipotential contact
(every metal part must have the same voltage) to the
equipotential terminal located on the cooking tops.
The manufacturer cannot be held responsible in the event that these instructions are not
respected.