Recommended Settings for Welding
1
Brackets, tubes and auxiliary part to bands
RANGE 1
ENERGY 3 to 7
2
Stainless steel wire from 0.010“ to 0.020“
RANGE 1
ENERGY 2 to 7
3
Stainless steel wire from 0.022“ to 0.045“
RANGE 2
ENERGY 4 to 7
4
TMA
–wires from 0.016“ to 0.022“
RANGE 1
ENERGY 5 to 7
5
TMA
– wires from 0.032“ to 0.036“
RANGE 2
ENERGY 6 to 7
The recommended settings are approximate values. Precise welds depend on
the thickness of materials and the pressure of the electrodes.