4
.
.
.
.
Maintenance of TB-1175
How to replace Iron tip and Heater Element
①
Turn off the power and wait until the iron tip cools down to
safety temperature.
②
Unlock the lock-wire.
③
After confirming the iron tip becomes cool enough,
hold the plastic area of iron tip and pull straight it out from
the iron grip.
Do NOT use any tools in order to pull out the tip.
*
To replace iron tip only
Proceed to
⑥
*
To replace both of iron tip and heater
Proceed to
④
④
Hold the heater element and pull straight it out from the
iron grip.
⑤
Insert a new heater element into the terminal hole securely.
There is no polarity, you can insert it any direction.
Align the edge of iron unit and the silver-colored-line on the
heater.
⑥
Insert a new iron tip into the iron grip
Align each point of arrow-mark on the tip and grip.
⑦
Finally, fasten the lock-wire.