8
③
Release
「◎」
key within 2 seconds after
「・・・」
is indicated at the display.
④
「
」
and
「
the previous set value
」
is alternately indicated at the display, then
the alarm setting mode is started.
⑤
The tens place blinks to enter a suitable digit by using
「▽」
or
「△」
key.
⑥
iress
「◎」
key to complete the setting.
⑦
The units place blinks to enter a suitable digit by using
「▽」
or
「△」
key.
⑧
iress
「◎」
key to complete the setting.
⑨
「
」
blinks at the display. iress
「◎」
key again, and the buzzer starts to
beep once to return to the operation mode.
7-(E): Auto tuning setting
Default: The value at the set temperature 350
℃
with JS-175-BK7-2C iron.
What the Auto tuning is.
The temperature control method of LA type soldering irons is “iID method”.
The Auto tuning function calculates the optimum iID value automatically when we
change iron tips or the SET IRON TIi TEMiERATURE.
Be sure to perform this function in order for irons to ensure optimum performances
When to perform the Auto tuning.
When use a soldering iron first time.
When replace soldering iron types. (JS-90
⇔
JS-175)
When replace soldering iron tips. (BK7 series
⇔
BK11 series)
When change the SET IRON TIi TEMiERATURE by more than 50
℃
.
When replace heaters.
Setting procedure
①
When the power is ON, turn it OFF once.