MW50

 

LA type soldering iron controller 

Instruction manual

QSS-4000

 

 

Date  prepared:  March  2019 

The  6

th

  edition 

JAPAN  BONKOTE  CO.,  LTD. 

 

 

 
 
 
 
 
 
 
 
 
 

PATRIOT

 

Содержание PATRIOT MW50

Страница 1: ...MW50 LA type soldering iron controller Instruction manual QSS 4000 Date prepared March 2019 The 6th edition JAPAN BONKOTE CO LTD PATRIOT ...

Страница 2: ...on lower limit setting 8 C Temperature recovery speed setting 9 D Upper limit setting of setting temperature 9 E Monitor indication of operation output amount 9 F Lock function 10 G Anti reset wind up setting 10 H Auto Power Down Auto Power Off setting 11 I PID value manual setting 13 J Device Number setting 15 7 Character List 16 8 How to maintenance 17 9 Standard specifications 17 10 Guarantee a...

Страница 3: ...rnt If you have to touch the tip like replacement of iron tip or parts turn off the power and pull out the power plug from the receptacle wait for a while and check if it has already cooled down sufficiently by using a thermometer or etc Do not overhaul the machine when the machine has trouble Otherwise it may cause malfunction electric shock and etc death at worst Contact with our customer servic...

Страница 4: ... electricity removal device wrist strap etc Odor is generated due to the use of solder and flux Be sure to ventilate work places E g fitting of ventilator etc Be sure to pull out the power plug when the machine is not used Be sure to grab the power plug instead of cable when inserting and pulling out the plug If the power voltage is changed from 100V to 220V make sure of confirm the specifications...

Страница 5: ...will be attached B Name of the body Front 5P Connector Power switch PV display Working temperature SV display Setting temperature key Speed setting key Function key key Setting value Down key key Setting value Up key Back 3P inlet Fuse holder 2pcs Modular jack 2pcs MW50 Controller 3P Power Cable ...

Страница 6: ...he Power cable into 3P inlet Connect the soldering iron to 5P connector at the front and lock it with rotating to right Please make sure the voltage of the soldering iron unit is applicable to the input voltage of MW50 controller ...

Страница 7: ... the one of controller should be the same Otherwise temperature control is unable to work The sensor type is set at the shipment How to confirm the sensor type A Controller At the operation mode or is indicated at left side of SV screen Controlling with J type indicates Controlling with K type indicates Please check the sensor type of the controller is same with the one of connecting soldering iro...

Страница 8: ...e Initial setting 350 Setting range 0 500 Ⅰ At the operation mode press key once and is indicated at PV screen Ⅱ Set the temperature by or key Ⅲ Press key once to return to operation mode Operation mode Setting temperature setting screen Operation mode Compensation of temperature differences Initial setting 0 Setting range 100 0 100 0 Ⅰ At the operation mode press key approx 3 seconds with pressin...

Страница 9: ...tion mode AT setting screen AT setting screen Operation mode あ Auto tuning It automatically calculate suitable PID value which control soldering iron Please make sure to do Auto tuning otherwise soldering iron may not perform with enough effect Attention Please make sure to doAuto tuning after reach to setting temperature Please do not touch the soldering iron during Auto tuning during AT is blink...

Страница 10: ...re Example The upper limit is set as 50 setting temperature is 350 It alarms when temperature become over 400 Set 0 when alarm function is unnecessary B Alarm function Lower limit setting Set the lower limit alarm of soldering temperature Initial setting 50 Ⅰ At the operation mode press key with pressing key is indicated at PV screen Ⅱ Push key 6 times is indicated at PV screen Ⅲ Input the value b...

Страница 11: ...mit of setting temperature Set the upper limit of setting temperature Initial setting 500 Setting range 0 500 Ⅰ At the operation mode press key with pressing key about 3 seconds is indicated at SV screen Ⅱ Push key twice is indicated at SV screen Ⅲ Input the value by or key at SV screen push key 6 times to return to operation mode Operation mode Input type setting screen Upper limit setting temper...

Страница 12: ...on mode Operation mode Input type setting screen Lock selection screen Operation mode Non lock Lock 1 Lock 2 Non lock Lock up all function setting except lock function Lock up all function setting except lock and temperature function G Anti reset wind up setting Control Overshooting Initial setting 18 Setting range 0 100 Ⅰ At the operation mode push key with pressing key is indicated at PV screen ...

Страница 13: ... Down and supplying electric power to the heater is stopped Power Off automatically when the iron tip temperature is no changed during the specified time available to set the time This function is also effective for saving energy and safety Setting of Auto Power Down time Initial setting 30 minutes Setting range 0 120 minutes Ⅰ At the operation mode press key with pressing key about 3 seconds to i...

Страница 14: ...conds is indicated at PV screen Ⅱ Push key 6 times to indicate is indicated at PV screen Ⅲ Input the value by or key push key 3 times to return to operation mode Operation mode Input type setting screen Auto Power down temperature setting screen Operation mode Auto Power Down temperature is the temperature duringAuto Power Down procedure Example When set Auto Power Down temperature to 150 controll...

Страница 15: ...Auto Power Down mode press or key more than 3 seconds to return to operation mode Return to operation mode from Auto Power Off mode Ⅰ Turn on the power again Manual operation Ⅰ At the operation mode after reach to setting temperature press or key more than 3 seconds to move to Auto Power Down mode Ⅱ At Auto Power Down mode press or key more than 3 seconds to return to operation mode I PID value ma...

Страница 16: ...ime Initial setting 38seconds Setting range 0 1000 Ⅰ At the operation mode push key with pressing key is indicated at PV screen Ⅱ Push key 2 times is indicated at PV screen Ⅲ Input the value by key push key 5 times to return to operation mode Operation mode AT setting screen Integration time setting screen Operation mode あ Setting of Derivative time Initial setting 8 seconds Setting range 0 300 Ⅰ ...

Страница 17: ... operation mode push key with pressing key in 3 seconds is indicated at PV screen Push key 4 times is indicated at PV screen Input Device Number by key on the SV screen then push key 6 times to return to operation mode Operation mode Input type setting screen Device No setting screen Operation mode Attention The numbering must start with 1 e g The first connected M50 s device number must be 1 and ...

Страница 18: ... setting Upper temperature setting Derivative time setting Compensate temperature Anti reset wind up setting Devise number setting Upper limit alarm setting Auto Power Down time setting Lower limit alarm setting Auto Power Down temperature setting Operation mode Auto Power Off time setting key Setting temperature change Key press Operation amount output key Setting temperature change ...

Страница 19: ...Weight Less than 750kg Fuse 3A Temperature control method PID control Auto tuning setting Temperature indication PV LED red SV LED green Error indication Over scale Temperature exceed upper limitation of indicatable temperature Error of sensor indication Under scale Temperature exceed lower limitation of indicatable temperature Opposite pole of sensor indication Material case Steel Power consumpti...

Страница 20: ...h to setting temperature Set upAnti reset wind function 10 Over shooting is large Key operation is unable Is the lock function effective Check the setting of Lock function 10 B Guarantee Our products are shipped after sever factory tests and inspections However if you find malfunctions or defects due to problems in workmanship or transportation please contact your dealers or us The guarantee perio...