HOW TO USE

 

1. Confirm the voltage of the soldering iron and the power source is the same. Insert the power plug into the outlet. 
   

- - -

  is indicated on the display and the power is being delivered to the iron. The soldering iron becomes Stand-by mode. 

 
2. Press and hold            button more than 3 seconds. 
    Default temperature                  is indicated on the display, and the power has been delivered to the heater in the iron. 
    Once                    is indicated on the display, release            button. 
 
3. When LED lamp change to          from          , you can start working. 

            When you start working, observe the solder in a pot has melted completely, the temperature rises higher and becomes stable   

           

We recommend that you start working after confirming the temperature is in stable. You could refer to the time in below chart. 

 

 

 
 
 
 
 

 

  Solder temperature reaches 90% of the set temperature. 

 

4. After work, press and hold              button more than 3 seconds until 

- - -

  is indicated on the display,   

    and then the LED lamp changes to        .    Check the display and release the button.   
    The latest set temperature should be applied whenever restarting the iron. 
 

HOW TO CHANGE SET TEMP.

 

    You can change the preset temperature by a long push or a short push of          or          buttons. 
    The short push changes the temperature by a single degree, and the long push changes it by 10 degrees at a time. 
    In case of the continuous soldering work for wires with large temperature capacity, the higher preset temperature is required. 

 

TEMP. CONTROL DIAL

 

    Using          dial, you can allow to correct the temperature discrepancy between the set temperature and the melted solder in a pot. 

            Be sure not to over-twist          dial.     

  The rotation angle from the initial position is 120 degrees maximum to left and right   

  Use a precision Philips screwdriver 

           

  Clockwise: Rise the tip temperature   

  Counterclockwise: Drop the tip temperature 

 

MEASURING THE MELTED SOLDER

 

  . When measuring the melted solder temperature by using a thermometer, do it after the time at the column C in the above chart,     
    so that you can obtain more precise value. 
 

LOCK FUNCTION

 

    Press and hold                    buttons simultaneously more than 3 seconds to lock or unlock the set temperature. 
 

 

 

Set temperature 

300

 

350

 

 

Solder has 

melted 

Solder temp. 

become stable 

 

Solder temp.   

arrive at set temp. 

Solder has 

melted 

Solder temp. 

become stable 

 

Solder temp.   

arrive at set temp 

DMSD-140 (240) -10 

5 min 

8 min 

12 min 

3 min 

5 min 30s 

9 min 30s 

DMSD-165-15 

8 min 

11 min 

20 min 

4 min 

9 min 30s 

15 min 

DMSD-1100 (2100) -30 

15 min 

20 min 

35 min 

8 min 

14 min 

25 min 

Temperature control dial 

 

UP 

DOWN 

Содержание DMSD-140-10

Страница 1: ...hexcludeapowercord Model No Power consumption Input voltage Insulation resistance Standardmini pot Weight Dimensions W L H Control Method Temp range I D Minipot DMSD 140 10 40W 100VAC 20MΩ SG10 DP10 465g 80 285 60 0volt Switch P control 50 500 φ 10x10D DMSD 165 15 65W SGP10 DP15 490g 80 285 60 φ 15x10D DMSD 1100 30 100W SG12 DP30 620g 80 285 67 φ 30x18D DMSD 240 10 40W 220VAC SG10 DP10 465g 80 285...

Страница 2: ...11D ECS 5 DMSD 165 153pinplug 65W CES 100 65E SGP10 DP15 SUCP 10 NA 20D DMSD 1100 303pinplug 100W CES 100 100E SG12 DP30 SUC 12 NA 30D DMSD 240 103pinplug 40W 220VAC CES 220 40E SG10 DP10 SUC 10 NA 11D DMSD 2100 303pinplug 100W CES 220 100E SG12 DP30 SUC 12 NA 30D Commonparts Gripcover GC R Grip GK DS Pushbuttonlabel DMSDTR Acrylicplate DS AK CONTROLPANEL A Temperaturecontroldial B Powerbutton C T...

Страница 3: ...ushof or buttons Theshortpushchangesthetemperaturebyasingledegree andthelongpushchangesitby10degreesatatime Incaseofthecontinuoussolderingworkforwireswithlargetemperaturecapacity thehigherpresettemperatureisrequired TEMP CONTROLDIAL Using dial youcanallowtocorrectthetemperaturediscrepancybetweenthesettemperatureandthemeltedsolderinapot Besurenottoover twist dial Therotationanglefromtheinitialposit...

Страница 4: ...lementoftemperature compensation Temperaturecompensationhasnot implemented Implementtemperature compensation Afterreplacementofaheater the solderingirondoesNOTheat Er2 isshownonthedisplay Oppositepolarityoftemperaturesensorterminal Correctthepolarity Settemperaturecannotbe adjusted 350 isshownonthedisplay Settemperaturemustbelocked Releasethelock function Powerisdelivering Er1 Er2 Er3 Error 350 Se...

Отзывы: