HOW TO USE
1. Confirm the voltage of the soldering iron and the power source is the same. Insert the power plug into the outlet.
「
- - -
」
is indicated on the display and the power is being delivered to the iron. The soldering iron becomes Stand-by mode.
2. Press and hold button more than 3 seconds.
Default temperature is indicated on the display, and the power has been delivered to the heater in the iron.
Once is indicated on the display, release button.
3. When LED lamp change to from , you can start working.
When you start working, observe the solder in a pot has melted completely, the temperature rises higher and becomes stable
We recommend that you start working after confirming the temperature is in stable. You could refer to the time in below chart.
※
Solder temperature reaches 90% of the set temperature.
4. After work, press and hold button more than 3 seconds until
「
- - -
」
is indicated on the display,
and then the LED lamp changes to . Check the display and release the button.
The latest set temperature should be applied whenever restarting the iron.
HOW TO CHANGE SET TEMP.
You can change the preset temperature by a long push or a short push of or buttons.
The short push changes the temperature by a single degree, and the long push changes it by 10 degrees at a time.
In case of the continuous soldering work for wires with large temperature capacity, the higher preset temperature is required.
TEMP. CONTROL DIAL
Using dial, you can allow to correct the temperature discrepancy between the set temperature and the melted solder in a pot.
Be sure not to over-twist dial.
※
The rotation angle from the initial position is 120 degrees maximum to left and right
※
Use a precision Philips screwdriver
※
Clockwise: Rise the tip temperature
※
Counterclockwise: Drop the tip temperature
MEASURING THE MELTED SOLDER
. When measuring the melted solder temperature by using a thermometer, do it after the time at the column C in the above chart,
so that you can obtain more precise value.
LOCK FUNCTION
Press and hold buttons simultaneously more than 3 seconds to lock or unlock the set temperature.
Set temperature
300
℃
350
℃
A
B
C
A
B
C
Solder has
melted
Solder temp.
become stable
※
※
※
※
Solder temp.
arrive at set temp.
Solder has
melted
Solder temp.
become stable
※
※
※
※
Solder temp.
arrive at set temp
DMSD-140 (240) -10
5 min
8 min
12 min
3 min
5 min 30s
9 min 30s
DMSD-165-15
8 min
11 min
20 min
4 min
9 min 30s
15 min
DMSD-1100 (2100) -30
15 min
20 min
35 min
8 min
14 min
25 min
Temperature control dial
UP
DOWN