background image

D_M3660REM_CMAN_VALL_00a 

12/03/2018 

521 Fairground Court   ●   Nashville, TN 37211   ●   USA 

Tel: (615) 244-2825   ●   Fax: (615) 244-2833   ●   Web: www.bonitron.com   ●   Email: [email protected] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание M3660REM

Страница 1: ...Web www bonitron com Tel 615 244 2825 Email info bonitron com Model M3660REM Regenerative Energy Monitor Customer Reference Manual ...

Страница 2: ...design develop and manufacture the quality industrial electronic systems demanded in today s market A strong academic background supported by continuing education is complemented by many years of hands on field experience A clear advantage Bonitron has over many competitors is combined on site engineering labs and manufacturing facilities which allows the engineering team to have immediate access ...

Страница 3: ...Below is a sampling of Bonitron s current product offering WORLD CLASS PRODUCTS Undervoltage Solutions Overvoltage Solutions Uninterruptible Power for Drives DC Bus Ride Thru Voltage Regulators Chargers and Dischargers Energy Storage Braking Transistors Braking Resistors Transistor Resistor Combo Line Regeneration Dynamic Braking for Servo Drives Common Bus Solutions Portable Maintenance Solutions...

Страница 4: ...M3660REM 4 This page intentionally left blank ...

Страница 5: ...tage 10 2 3 General Specifications 11 Table 2 3 General Specifications Table 11 2 4 General Precautions and Safety Warnings 12 3 INSTALLATION INSTRUCTIONS 13 3 1 Environment 13 3 2 Wiring and Customer Connections 13 4 OPERATION 15 4 1 Functional Description 15 4 2 Features 16 4 2 1 Hardware 16 Figure 4 1 Cables 16 4 2 2 Display 17 Figure 4 2 Front Panel 17 4 2 3 Screens Menu Navigation 18 Figure 4...

Страница 6: ...M3660REM 6 This page intentionally left blank ...

Страница 7: ...e 1 2 PURPOSE AND SCOPE This manual is a user s guide for the model M3660REM It will provide the user with the necessary information to successfully connect and operate the M3660REM In the event of any conflict between this document and any publication and or documentation related to any associated hardware capacitor bank etc the latter shall have precedence 1 3 MANUAL VERSION AND CHANGE RECORD Th...

Страница 8: ...ntifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss CAUTION CAUTION Identifies information about practices or circumstances that can lead to property damage or economic loss Attentions help you identify a potential hazard avoid a hazard and recognize the consequences CAUTION CAUTION Heat or burn hazard Identifies a stateme...

Страница 9: ... by measuring the peak and average currents as well as calculating the total energy in the Event This can be helpful information for system engineers to verify that the braking chopper and or load resistor are appropriately sized and rated for the requirements of the application 2 1 RELATED PRODUCTS BRAKING TRANSISTORS M3575T Standard Duty Braking Transistor up to 600A M3452 Heavy Duty Braking Tra...

Страница 10: ... SYSTEM VOLTAGE RATING The System Voltage rating indicates the maximum AC system voltage for which the unit is designed to operate Table 2 1 System Voltage RATING CODE SYSTEM VOLTAGE C Up to 600VAC MAX CURRENT RATING The max current rating indicates the maximum DC load current the unit can measure M3660REM C BASE MODEL NUMBER SYSTEM VOLTAGE CODE MAX CURRENT RATING 2000 ...

Страница 11: ...ATION System Voltage Up to 600 VAC Braking Current 200A 2000A DC Controls Six display soft keys Display Four line eighty character LCD 4x20 Unit Size H x W x D 13 4 x 11 6 x 6 0 Weight 6 lbs Storage Temp 20 C to 65 C Humidity Below 90 non condensing Atmosphere Free of corrosive gas and conductive dust ...

Страница 12: ...ING RESISTOR TERMINALS ENSURE THAT THE SYSTEM IS POWERED OFF NEVER OPERATE THIS PRODUCT WITH THE ENCLOSURE COVER REMOVED DANGER NEVER ATTEMPT TO SERVICE THIS PRODUCT CERTAIN PARTS INSIDE THIS PRODUCT MAY GET HOT DURING OPERATION BEFORE CONNECTING THIS DEVICE TO ANY OTHER PRODUCT BE SURE TO REVIEW ALL DOCUMENTATION OF THAT PRODUCT FOR PERTINENT SAFETY PRECAUTIONS ANY QUESTIONS AS TO APPLICATION INS...

Страница 13: ...n operation the unit should be used only in dry clean areas Ensure that the interior of the unit casing is kept dry 3 2 WIRING AND CUSTOMER CONNECTIONS The M3660REM is not intended for permanent installation into a drive cabinet it was designed as a portable unit to be used as needed Therefore it has no installation wiring requirements ...

Страница 14: ...M3660REM 14 This page intentionally left blank ...

Страница 15: ...ched during the Event Note the max save Length of a single saved Event is 30min if an Event lasts longer than this limit it will automatically be split over multiple entries For example assume a braking Event that lasted 42m 27s This will be saved as 2 Events the first with a Length of 30mins and the second with a Length of 12m 27s In addition to the individual Event records the Regen Monitor keep...

Страница 16: ...3 cable commonly used with desktop computers to provide power to the unit 4 2 1 2 VOLTAGE LEADS The two voltage cables feature a large claw for easy connection to the load terminals with a finger safe 4mm banana plug termination at the unit 4 2 1 3 CURRENT CLAMP The provided Pico TA167 200A 2000A Current Probe connects to the BNC terminal on the front panel of the unit Figure 4 1 Cables ...

Страница 17: ...uttons corresponds to a direction up down left or right Up and Down move the cursor among menu items On screens where numbers are input by the user the Left and Right buttons move the cursor while the Up and Down buttons change the selected digits On some screens certain buttons may have no function at all 4 2 2 2 ENTER AND CANCEL BUTTON The green Enter button selects menu options On a menu screen...

Страница 18: ...3 1 2 CONFIGURATION The Configuration Menu contains all the settings that are user adjustable Set Date Time The user can adjust the full timestamp Year Month Day Hour Minute Seconds if ever necessary Set Current Clamp The user can swap between 200A and 2000A settings Important The Clamp setting in the unit MUST match the Range selector on the Pico probe otherwise the Current and Energy calculation...

Страница 19: ...User s Manual 19 Figure 4 3 Menu Tree Main Menu Clear Records Status Configuration Records Individual Events Lifetime Stats Set Date Time Set Current Clamp Clear Event Records Clear All Data ...

Страница 20: ...r cable is connected firmly to the unit and to a functioning power source at the correct voltage If both connections and the power supply are good make sure the input circuit breaker has not tripped Unit never goes ACTIVE when a Braking Event occurs Check the Voltage cables Ensure they are firmly connected between the unit and the load and that the polarity is correct Incorrect values for the Even...

Страница 21: ...User s Manual 21 This page intentionally left blank ...

Страница 22: ...G DATA 6 1 RATINGS CHART Table 6 1 Ratings Chart Input Voltage 110 120VAC System Voltage 600VAC Max Braking Voltage 1000VDC Max Braking Current 2000A Table 6 2 Dimensions Height 6 in with top closed Width 13 4 in Depth 11 6 in ...

Страница 23: ...User s Manual 23 This page intentionally left blank ...

Страница 24: ......

Страница 25: ......

Страница 26: ...D_M3660REM_CMAN_VALL_00a 12 03 2018 521 Fairground Court Nashville TN 37211 USA Tel 615 244 2825 Fax 615 244 2833 Web www bonitron com Email info bonitron com ...

Отзывы: